For more information on other products please click below.
Back to Product Index Back to Product Index Back to Product Index
Steam Computer – DP Meter (AGA – 3)
The 515-SC05 application measures the volume, mass and energy content of steam by using single or stacked differential pressure flow inputs in conjunction with a temperature and/or pressure input.
A selection of various modes makes it suitable for many steam applications. The flow is calculated according to the AGA-3 differential pressure equations. The flow calculations incorporate the conditions at which the flowmeter was calibrated and accurately account for thermal expansion effects.
The instrument calculates the mass flow and energy according to the IAPWS Industrial Formulation (1997) for the thermodynamic properties of steam. The equations use pressure and temperature values to determine the specific volume and the specific enthalpy.
Calculations
The steam energy calculations are based on the IAPWS Industrial Formulation (1997).
Superheated steam regions are:
• 0°C < t < 800°C P < 100MPa
• 32°F < t < 1472°F P < 14500psia
• 800°C < t < 2000°C P < 10MPa
• 1472°F < t < 3632°F P < 1450psia
Saturated steam regions are:
• 0°C < t < 374°C (critical temperature)
• 32°F < t < 705°F
• P < 22MPa (critical pressure)
• P < 3190psia
Water region is:
• 0°C < t < t saturation at system pressure
• 32°C < t < t saturation at system pressure
Formulas:
• Volume flow = Mass flow x Specific volume
• Energy flow = Mass flow x Specific enthalpy
Features
Tailored for differential pressure meters with single or stacked transmitters
Uses IAPWS-IF97 steam calculation
Suitable for Water, Saturated and Superheated steam applications
AGA-3 DP flow calculations
Allows for non-linear correction
Selection of second language and user tags
RTC logging with over 1000 entries
Infra-red communications port on front panel
Pulse width and scaling of pulse output
4-20mA retransmission
Selectable protocols on serial ports including Modbus RTU and printer output
Front panel adjustment of 8-24V DC output voltage
Backlit Display
LCD Backup Typical plant diagram
Downloads
Related Accessories
Software – Program Manager (Download)
Software – DataMod Tool
IP65 – Stainless Steel (Custom)
IP66 – Weatherproof Enclosure
PR-00 – Thermal Panel Printer
PR-01 – Roll Printer (Panel Mount Impact)
PR-03 – Desktop 240VAC 80 Col
PR-02 – Desktop 24VDC or 240VAC
PR-04 – Thermal Ticket Printer