OUR PRODUCTS ABOUT CONTREC MEET OUR TEAM NEWS CONTACT

Controllers by Series

100 Series 200 Series 400 Series 515 Series Trac-50 LoadPro® Accessories

Products by Functionality

Accessories

Batch Controllers

- Batch/Additive Controllers

- Batch/Flow Controllers

- Batch/Ratio Controllers

- Standard Batch Controllers

Density Computers

Flow Computers

- General Flow Computers

- General Gas Flow Computers

- Heat Calculators

- Mass Flow Computers

- Master Proving Flow Computers

- Natural Gas Flow Computers

- Open Channel Flow Computers

- Special Application Flow Computers

- Steam Flow Computers

Flow Rate Totalisers

- Hazardous Area Flow Rate Totalisers

- Safe Area Flow Rate Totalisers

Level IndicatorsLoad ControllersSite AccessTruck Registers

Products by Industries

AviationBarge & Rail TransportBiofuels ProductionChemical & PharmaceuticalFood & BeverageFuel DepotGas Storage & DistributionMineral MiningNuclearOil & GasOil RefineryPower/EnergyWater & Waste Treatment

Downloads

Declarations of Conformity Hazardous Area Approvals Contrec Quality Certificates Technical Notes Software Downloads Other

515-SC03 – Steam Computer – Volume, Mass & Energy

Steam Flow Computer

The 515-SC03 application measures the volume, mass and energy content of steam by using single or stacked differential pressure mass flow inputs in conjunction with a temperature and/or pressure input. A selection of various modes makes it suitable for many steam applications. The instrument calculates the flow according to generic differential pressure equations and incorporates the conditions at which the flowmeter was calibrated. The instrument calculates the mass flow and energy according to the IAPWS Industrial Formulation (1997) for the thermodynamic properties of steam. The equations use the pressure and temperature values to determine the specific volume and the specific enthalpy. A specific enthalpy adjustment can be used to offset any initial energy.

Calculations

The steam energy calculations are based on the IAPWS Industrial Formulation (1997).

Superheated steam regions are:
• 0°C < t < 800°C
• 32°F < t < 1472°F
• P < 100 MPa
• P < 14500 psia
• 800°C < t < 2000°C
• 1472°F < t < 3632°F
• P < 10 MPa
• P < 1450 psia

Saturated steam regions are:
• 0°C < t < 374°C (critical temperature)
• 32°F < t < 705°F
• P < 22 MPa (critical pressure)
• P < 3190 psia

Water region is:
• 0°C < t < tsaturation at system pressure
• 32°F < t < tsaturation at system pressure

Formulas:
• Volume flow = Mass flow x Specific volume
• Energy flow = Mass flow x Net SE
• Net SE = SE – SEadj (if SE > SEadj otherwise 0)
• SE = Specific Enthalpy

Displayed Information

The front panel display shows the current values of the input variables and the results of the calculations. A list of the variables for this application and their type (total or rate) is shown at the end of this document.

The instrument can be supplied with a real-time clock for data logging of over 1000 entries of the variables as displayed on the main menu.

Communications

There are two communication ports available as follows:
• COM-1 RS-232 port
• COM-2 RS-485 port (optional) or Ethernet (optional)

All types of ports can be used for remote data reading, while RS-232 and RS-485 serial ports can be used for printouts and for uploading and downloading of the application software to the instrument.

Isolated Outputs

The opto-isolated outputs can re-transmit any main menu variable. The type of output is determined by the nature of the assigned variable. Totals are output as pulses and rates are output as 4-20 mA signals. One output is standard, a second output is available as an option.

Relay Outputs

The relay alarms can be assigned to any of the main menu variables of a rate type. The alarms can be fully configured including hysteresis. Two relays are standard with two additional relays available as an option.

Software Configuration

The instrument can be programmed to suit the particular application needs and the flexible I/O can be assigned as required. Program settings can be changed either via the front panel (depending on assigned access levels) or via the 500 Series Program Manager (500-PM software).
The instrument stores all set-up parameters, totals and logged data in non-volatile memory with at least 30 years retention.

For more information on other products please click below.

Back to Product Index Back to Product Index Back to Product Index

Features

Tailored for differential pressure mass meters with single or stacked transmitters
Generic differential pressure flow calculations
Uses IAPWS-IF97 steam calculation
Suitable for Water, Saturated and Superheated steam applications
Allows for Specific Enthalpy (initial energy) offset
Selection of Detail or Basic main menu to suit operator and application
Selection of second language and user tags
RTC logging with over 1000 entries
Programmable pulse width and scaling of pulse output
4-20 mA retransmission
RS232 and RS485 or Ethernet (optional) serial ports
Modbus RTU, Printer and other serial port protocols

Typical plant diagram

Downloads

Related Accessories

Back to Index

Request a Quote/Enquiry








    Features

    Tailored for differential pressure mass meters with single or stacked transmitters
    Generic differential pressure flow calculations
    Uses IAPWS-IF97 steam calculation
    Suitable for Water, Saturated and Superheated steam applications
    Allows for Specific Enthalpy (initial energy) offset
    Selection of Detail or Basic main menu to suit operator and application
    Selection of second language and user tags
    RTC logging with over 1000 entries
    Programmable pulse width and scaling of pulse output
    4-20 mA retransmission
    RS232 and RS485 or Ethernet (optional) serial ports
    Modbus RTU, Printer and other serial port protocols

    Typical plant diagram

    Downloads

    Compare with similar products

    X

    Worldwide Sales Offices

    European, Middle East and UK

    +44 (0) 1422 829944

    [email protected]

    Sales Director: Craig Naylor – [email protected]

    Sales and General Enquiries – [email protected]

    Marketing: Lucy Wood – [email protected]

    Americas and Canada Sales

    +1 205 685 3000

    +1 205 685 3001

    [email protected]

    General Enquiries – [email protected]

    Australia and Asia Sales

    +61 (0) 0413 505 114

    [email protected]

    Managing Director: Paul Chaston – [email protected]

    Enquiry Form

























          X

























                X

                European, Middle East and UK

                Contrec Limited

                Unit G8, Navigation Close

                Lowfields Business Park

                Elland, West Yorkshire

                HX5 9HB

                United Kingdom.

                +44 (0) 1422 829944 [email protected]

                Sales Director: Craig Naylor

                [email protected]

                Sales and general enquiries

                [email protected]

                Marketing: Lucy Wood

                [email protected]
                X

                Americas and Canada Sales

                Contrec USA

                916 Belcher Drive

                Pelham, Alabama, 35124

                United States.

                +1 205 685 3000 +1 205 685 3001 [email protected]
                X

                Australia and Asia Sales

                Contrec Systems Pty Ltd

                5 Norfolk Ave, Ringwood

                Melbourne, Victoria, 3134

                Australia.

                +61 (0) 0413 505 114 [email protected]

                Managing Director: Paul Chaston

                [email protected]
                ©2025 Contrec Limited - This website was designed and developed by LASERLINES Creative Limited

                Whilst every effort has been made to ensure the accuracy of the information/material contained on our web site, we cannot guarantee that it is free from errors or omissions.