OUR PRODUCTS ABOUT CONTREC MEET OUR TEAM NEWS CONTACT

Controllers by Series

100 Series 200 Series 400 Series 515 Series Trac-50 LoadPro® Accessories

Products by Functionality

Accessories

Batch Controllers

- Batch/Additive Controllers

- Batch/Flow Controllers

- Batch/Ratio Controllers

- Standard Batch Controllers

Density Computers

Flow Computers

- General Flow Computers

- General Gas Flow Computers

- Heat Calculators

- Mass Flow Computers

- Master Proving Flow Computers

- Natural Gas Flow Computers

- Open Channel Flow Computers

- Special Application Flow Computers

- Steam Flow Computers

Flow Rate Totalisers

- Hazardous Area Flow Rate Totalisers

- Safe Area Flow Rate Totalisers

Level IndicatorsLoad ControllersProcess IndicatorsSite AccessTruck Registers

Products by Industries

AviationBarge & Rail TransportBiofuels ProductionChemical & PharmaceuticalFood & BeverageFuel DepotGas Storage & DistributionMineral MiningNuclearOil & GasOil RefineryPower/EnergyWater & Waste Treatment

Downloads

EU Declarations of Conformity Hazardous Area Approvals Contrec Quality Certificates Technical Notes Software Downloads Other

515-SC06 – Steam Computer – DP Meter (Volumetric)

Steam Computer – DP Meter (Volumetric)

The 515-SC06 application measures the volume, mass and energy content of steam by using single or stacked differential pressure volumetric flow inputs in conjunction with a temperature and/or pressure input.

A selection of various modes makes it suitable for many steam applications. The instrument calculates the flow according to generic differential pressure equations and incorporates the conditions at which the flowmeter was calibrated.

The instrument calculates the mass flow and energy according to the IAPWS Industrial Formulation (1997) for the thermodynamic properties of steam. The equations use pressure and temperature values to determine the specific volume and the specific enthalpy.

Calculations

The steam energy calculations are based on the IAPWS Industrial Formulation (1997).

Superheated steam regions are:
• 0°C < t < 800°C P < 100MPa
• 32°F < t < 1472°F P < 14500psia
• 800°C < t < 2000°C P < 10MPa
• 1472°F < t < 3632°F P < 1450psia

Saturated steam regions are:
• 0°C < t < 374°C (critical temperature)
• 32°F < t < 705°F
• P < 22MPa (critical pressure)
• P < 3190psia

Water region is:
• 0°C < t < t saturation at system pressure
• 32°C < t < t saturation at system pressure

Formulas:
• Mass flow = Volume flow/Specific volume
• Energy flow = Mass flow x Specific enthalpy

For more information on other products please click below.

Back to Product Index Back to Product Index Back to Product Index

Features

Tailored for differential pressure volumetric meters with single or stacked transmitters
Generic differential pressure flow calculations
Uses IAPWS-IF97 steam calculation
Suitable for Water, Saturated and Superheated steam applications
Allows for square law and non-linear correction
Selection of second language and user tags
RTC logging with over 1000 entries
Infra-red communications port on front panel
Pulse width and scaling of pulse output
4-20mA retransmission
Selectable protocols on serial ports including Modbus RTU and printer output
Front panel adjustment of 8-24V DC output voltage
Backlit Display
LCD Backup

Typical plant diagram

Downloads

Related Accessories

BACK TO INDEX

Request a Quote/Enquiry

OPEN MESSAGE

Features

Tailored for differential pressure volumetric meters with single or stacked transmitters
Generic differential pressure flow calculations
Uses IAPWS-IF97 steam calculation
Suitable for Water, Saturated and Superheated steam applications
Allows for square law and non-linear correction
Selection of second language and user tags
RTC logging with over 1000 entries
Infra-red communications port on front panel
Pulse width and scaling of pulse output
4-20mA retransmission
Selectable protocols on serial ports including Modbus RTU and printer output
Front panel adjustment of 8-24V DC output voltage
Backlit Display
LCD Backup

Typical plant diagram

Downloads

Compare with similar products

X

Worldwide Sales Offices

European, Middle East and UK

+44 (0) 1422 829944

[email protected]

Sales Director: Craig Naylor – [email protected]

Sales and General Enquiries – [email protected]

Marketing: Lucy Wood – [email protected]

Americas and Canada Sales

+1 205 685 3000

+1 205 685 3001

[email protected]

General Enquiries – [email protected]

Australia and Asia Sales

+61 (0) 0413 505 114

[email protected]

Managing Director: Paul Chaston – [email protected]

World Map

Enquiry Form

























        X

























              X

              European, Middle East and UK

              Contrec Limited

              Unit G8, Navigation Close

              Lowfields Business Park

              Elland, West Yorkshire

              HX5 9HB

              United Kingdom.

              +44 (0) 1422 829944 [email protected]

              Sales Director: Craig Naylor

              [email protected]

              Sales and general enquiries

              [email protected]

              Marketing: Lucy Wood

              [email protected]
              X

              Americas and Canada Sales

              Contrec USA

              916 Belcher Drive

              Pelham, Alabama, 35124

              United States.

              +1 205 685 3000 +1 205 685 3001 [email protected]
              X

              Australia and Asia Sales

              Contrec Systems Pty Ltd

              5 Norfolk Ave, Ringwood

              Melbourne, Victoria, 3134

              Australia.

              +61 (0) 0413 505 114 [email protected]

              Managing Director: Paul Chaston

              [email protected]
              ©2026 Contrec Limited - This website was designed and developed by LASERLINES Creative Limited

              Whilst every effort has been made to ensure the accuracy of the information/material contained on our web site, we cannot guarantee that it is free from errors or omissions.