For more information on other products please click below.
Back to Product Index Back to Product Index Back to Product Index
Steam Computer – DP Meter (ISO/Cone)
The 515-SC04 application measures the volume, mass and energy content of steam by using single or stacked differential pressure flow inputs in conjunction with a temperature and/or pressure input.
A selection of various modes makes it suitable for many steam applications. Flow is calculated according to equations for ISO 5167 or V-Cone meters and accurately accounts for thermal expansion effects.
The energy calculations are based on the IAPWS Industrial Formulation (1997) for the thermodynamic properties of steam. Pressure and temperature values are used to determine the specific volume and enthalpy. The instrument also calculates the isentropic exponent and absolute viscosity which are required for the differential flowrate calculations.
Calculations
The steam energy calculations are based on the IAPWS Industrial Formulation (1997).
Superheated steam regions are:
• 0°C < t < 800°C P < 100MPa
• 32°F < t < 1472°F P < 14500psia
• 800°C < t < 2000°C P < 10MPa
• 1472°F < t < 3632°F P < 1450psia
Saturated steam regions are:
• 0°C < t < 374°C (critical temperature)
• 32°F < t < 705°F
• P < 22MPa (critical pressure)
• P < 3190psia
Water region is:
• 0°C < t < t saturation at system pressure
• 32°C < t < t saturation at system pressure
Formulas:
• Volume flow = Mass flow x Specific volume
• Energy flow = Mass flow x Specific enthalpy
Features
Tailored for differential pressure meters with single or stacked transmitters
Uses IAPWS-IF97 steam calculation
Suitable for Water, Saturated and Superheated steam applications
ISO 5167 (2003) DP flow calculations, 9 meter types
V-Cone DP flow calculations, 2 cone types
Allows for non-linear correction
Selection of second language and user tags
RTC logging with over 1000 entries
Infra-red communications port on front panel
Pulse width and scaling of pulse output
4-20mA retransmission
Selectable protocols on serial ports including Modbus RTU and Printer output
Front panel adjustment of 8-24V DC output voltage
Backlit display
LCD Backup Typical plant diagram
Downloads
Related Accessories
Software – Program Manager (Download)
Software – DataMod Tool
IP65 – Stainless Steel (Custom)
IP66 – Weatherproof Enclosure
PR-00 – Thermal Panel Printer
PR-01 – Roll Printer (Panel Mount Impact)
PR-02 – Desktop 24VDC or 240VAC
PR-03 – Desktop 240VAC 80 Col
PR-04 – Thermal Ticket Printer