OUR PRODUCTS ABOUT CONTREC MEET OUR TEAM NEWS CONTACT

Controllers by Series

100 Series 200 Series 400 Series 515 Series Trac-50 LoadPro® Accessories

Products by Functionality

Accessories

Batch Controllers

- Batch/Additive Controllers

- Batch/Flow Controllers

- Batch/Ratio Controllers

- Standard Batch Controllers

Density Computers

Flow Computers

- General Flow Computers

- General Gas Flow Computers

- Heat Calculators

- Mass Flow Computers

- Master Proving Flow Computers

- Natural Gas Flow Computers

- Open Channel Flow Computers

- Special Application Flow Computers

- Steam Flow Computers

Flow Rate Totalisers

- Hazardous Area Flow Rate Totalisers

- Safe Area Flow Rate Totalisers

Level IndicatorsLoad ControllersSite AccessTruck Registers

Products by Industries

AviationBarge & Rail TransportBiofuels ProductionChemical & PharmaceuticalFood & BeverageFuel DepotGas Storage & DistributionMineral MiningNuclearOil & GasOil RefineryPower/EnergyWater & Waste Treatment

515-LM02 – Single Tank Level Monitor

The 515 LM02 single tank level monitor,  monitors and measures the level of product in a single tank. The instrument uses the 4-20mA signal from a wide range of level sensors, including pressure transmitters, ultrasonic sensors and capacitance probes.

The level monitor provides a 20 point strapping table and product density for level to volume and volume to mass conversions. The instrument can display Volume, Percentage Full and Mass as well as Level. Relay alarms are freely assignable as high or low alarms and an open collector output is provided for programmable level control.

A sub-menu gives full details of alarm status and can offer direct access to change the alarm setpoints. The instrument also has density correction available for pressure level sensors to cater for a deviation in product density.

Calculations

Calculations are based on the analog input signal representing the product level in the tank:
• level = (Lmax – Lmin) x A + L min
• volume = (Vmax – Vmin) x A* + Vmin
• mass = volume x density

Where:
• A = normalised input signal with density correction.
• A* = A for linear tanks.
• A* = f(A) for non-linear tanks.
• f(A) = level to volume normalised strapping table.

Displayed Information

The front panel display shows the current values of the input variables and the results of the calculations. A list of the variables for this application and their type (total or rate) is shown at the end of this document.

The instrument can be supplied with a real-time clock for data logging of over 1000 entries of the variables as displayed on the main menu.

Communications

There are two communication ports available as follows:
• RS-232 port
• RS-485 port (optional)

The ports can be used for remote data reading, printouts and for initial application loading of the instrument.

Isolated Outputs

The opto-isolated outputs can re-transmit any main menu variable. The type of output is determined by the nature of the assigned variable. Totals are output as pulses and rates are output as 4-20 mA signals. One output is standard, a second output is available as an option.

Relay Outputs

The relay alarms can be assigned to any of the main menu variables of a rate type. The alarms can be fully configured including hysteresis. Two relays are standard with an additional two available in the advanced option.

Software Configuration

The instrument can be further tailored to suit specific application needs including units of measurement, custom tags, second language or access levels. A distributor can configure these requirements before delivery.

Instrument parameters including units of measurement can be programmed in the field, according to the user access levels assigned to parameters by the distributor.

All set-up parameters and logged data are stored in nonvolatile memory with at least 30 years retention.

To see our full rage of Tank Level Monitors, please click here.

For more information on other products please click below.

Back to Product Index Back to Product Index Back to Product Index

Related Accessories

Back to Index

Request a Quote/Enquiry








    Features

    20 Point level to volume strapping table
    Level control output
    Accepts level and pressure (product head) sensors
    Density correction available for pressure level sensors
    Provides volume to mass conversion via density value
    Freely assignable alarms for high or low levels
    Selection of Detail or Basic main menu to suit operator and application
    Selection of second language and user tags
    RTC logging with over 1000 entries
    4-20mA retransmission
    RS232 and RS485 or Ethernet (optional) serial ports
    Modbus RTU, Printer and other serial port protocols
    Front panel adjustment of 8-24V DC output voltage
    Backlit display

    Typical plant diagram

    Downloads

    X

    Worldwide Sales Offices

    European, Middle East and UK

    +44 (0) 1422 829944

    [email protected]

    Sales Director: Craig Naylor – [email protected]

    Sales and General Enquiries – [email protected]

    Marketing: Lucy Wood – [email protected]

    Americas and Canada Sales

    +1 205 685 3000

    +1 205 685 3001

    [email protected]

    General Enquiries – [email protected]

    Australia and Asia Sales

    +61 (0) 0413 505 114

    [email protected]

    Managing Director: Paul Chaston – [email protected]

    Enquiry Form

























          X

























                X

                European, Middle East and UK

                Contrec Limited

                Unit G8, Navigation Close

                Lowfields Business Park

                Elland, West Yorkshire

                HX5 9HB

                United Kingdom.

                +44 (0) 1422 829944 [email protected]

                Sales Director: Craig Naylor

                [email protected]

                Sales and general enquiries

                [email protected]

                Marketing: Lucy Wood

                [email protected]
                X

                Americas and Canada Sales

                Contrec USA

                916 Belcher Drive

                Pelham, Alabama, 35124

                United States.

                +1 205 685 3000 +1 205 685 3001 [email protected]
                X

                Australia and Asia Sales

                Contrec Systems Pty Ltd

                5 Norfolk Ave, Ringwood

                Melbourne, Victoria, 3134

                Australia.

                +61 (0) 0413 505 114 [email protected]

                Managing Director: Paul Chaston

                [email protected]
                ©2025 Contrec Limited - This website was designed and developed by LASERLINES Creative Limited

                Whilst every effort has been made to ensure the accuracy of the information/material contained on our web site, we cannot guarantee that it is free from errors or omissions.