For more information on other products please click below.
Back to Product Index Back to Product Index Back to Product Index
The 515 MP02 application measures the mass flow of a product.
The instrument uses the frequency output from a mass flowmeter and has an additional “master meter” input and Meter Factor for in-line proving.
The master meter input allows an “on the fly” proving run to be carried out against the line meter without interrupting the flow. A recommended Meter Factor is calculated and can be entered to ensure accurate measurement for current flow conditions or to cater for a slight deterioration in the line meter.
The flow computer maintains the Line flowrate and total independently of the proving totals. Proving runs can be controlled via the RTU Modbus communications or via rear panel logic inputs.
Features
Provides “on the fly” proving
Remote Modbus or rear panel control
Tailored for mass frequency flow and master meter inputs
Includes Live and Average Temperature and Pressure values
Temperature and Pressure averaged over flow (not time)
Selection of second language and user tags
RTC logging with over 1000 entries
Programmable pulse width and scaling of pulse output
4-20 mA retransmission
RS-232 and RS-485 (optional) serial ports
Modbus RTU, Printer and other serial port protocols
Front panel adjustment of 8-24 V DC output voltage
Backlit display Typical plant diagram
Downloads
Related Accessories
Software – Program Manager (Download)
Software – DataMod Tool
IP65 – Stainless Steel (Custom)
IP66 – Weatherproof Enclosure
PR-00 – Thermal Panel Printer
PR-01 – Roll Printer (Panel Mount Impact)
PR-03 – Desktop 240VAC 80 Col
PR-02 – Desktop 24VDC or 240VAC
PR-04 – Thermal Ticket Printer