OUR PRODUCTS ABOUT CONTREC MEET OUR TEAM NEWS CONTACT

Controllers by Series

100 Series 200 Series 400 Series 515 Series Trac-50 LoadPro® Accessories

Products by Functionality

Accessories

Batch Controllers

- Batch/Additive Controllers

- Batch/Flow Controllers

- Batch/Ratio Controllers

- Standard Batch Controllers

Density Computers

Flow Computers

- General Flow Computers

- General Gas Flow Computers

- Heat Calculators

- Mass Flow Computers

- Master Proving Flow Computers

- Natural Gas Flow Computers

- Open Channel Flow Computers

- Special Application Flow Computers

- Steam Flow Computers

Flow Rate Totalisers

- Hazardous Area Flow Rate Totalisers

- Safe Area Flow Rate Totalisers

Level IndicatorsLoad ControllersSite AccessTruck Registers

Products by Industries

AviationBarge & Rail TransportBiofuels ProductionChemical & PharmaceuticalFood & BeverageFuel DepotGas Storage & DistributionMineral MiningNuclearOil & GasOil RefineryPower/EnergyWater & Waste Treatment

515-LK01 – Leak Monitor

Leak Monitor

The 515-LK01 Leak Monitor is designed to be part of an accurate and reliable monitoring and alarm system for critical processes where not more than acceptable volume is allowed to pass in a given time. A primary example of this is in the cooling processes in power generation plants where it is critical to monitor the loss/usage of coolant (water) in a system. This can be important to monitor for cooling performance or environmental concerns.

This application operates as a “Leak Monitor” with a programmable preset value and a programmable internal timer to activate an alarm when the preset value is reached before the timer expires. It is designed to operate with an external NO/NC relay to act as a fail safe relay with the ability to raise an alarm on a power fail or whenever the unit is not monitoring the rate of leakage.

The instrument is compatible with a wide range of volumetric frequency flowmeter outputs, including millivolt signals, reed switches, Namur proximity switches and pulse trains.

Calculations

The total and flowrate are derived from accurately measured frequency and the number of received pulses:
• volume = pulses / k-factor
• volume flow = frequency / k-factor

Leak Timer is maintained accurately by a precise internal clock and is displayed and recorded in minutes and seconds.

Displayed Information

The front panel display shows the current values of the input variables and the results of the calculations. A list of the variables for this application and their type (total or rate) is shown at the end of this document. The instrument can be supplied with a real-time clock for storage of up to 1000 transactions with time and date stamps.

Communications

There are two communication ports available as follows:
• COM-1 RS-232 port
• COM-2 RS-485 port (optional) or Ethernet (optional)

The ports are available for remote data reading, printouts and for initial application loading of the instrument.

Isolated Outputs

The opto-isolated outputs are dedicated logic outputs, where OUT1 provides an Exception Active signal and OUT2 provides a Monitor Mode Active signal. One output is standard, a second output is available as an option.

Relay Outputs

The relay output 1 is dedicated as the Primary Status Relay (monitor mode) and relay output 2 is able to be used as assignable alarm. The advanced option provides another two relays that can be used as fully programmable alarms for any rate type variable.

Software Configuration

The instrument can be programmed to suit the particular application needs and the flexible I/O can be assigned as required. Program settings can be changed either via the front panel (depending on assigned access levels) or via the 500 Series Program Manager (500-PM software).
The instrument stores all set-up parameters, totals and logged data in non-volatile memory with at least 30 years retention.

For more information on other products please click below.

Back to Product Index Back to Product Index Back to Product Index

Related Accessories

Back to Index

Request a Quote/Enquiry








    Features

    Monitors critical applications as Leakage Vs Time
    Alarms on unacceptable degree of leakage
    Tailored for volumetric frequency flowmeters
    Leak Preset value is accessed via the front panel
    Remote RUN, STOP & RESET inputs available
    Outputs and relays used to indicate leak monitor status
    Allows for non-linear correction of flow input
    Storage of 1000 transactions with time and date stamp
    Selection of Detail or Basic main menu to suit operator and application
    Available protocols on communication ports including Printers, Modbus RTU & TCP/IP

    Typical plant diagram

    Downloads

    X

    Worldwide Sales Offices

    European, Middle East and UK

    +44 (0) 1422 829944

    [email protected]

    Sales Director: Craig Naylor – [email protected]

    Sales and General Enquiries – [email protected]

    Marketing: Lucy Wood – [email protected]

    Americas and Canada Sales

    +1 205 685 3000

    +1 205 685 3001

    [email protected]

    General Enquiries – [email protected]

    Australia and Asia Sales

    +61 (0) 0413 505 114

    [email protected]

    Managing Director: Paul Chaston – [email protected]

    Enquiry Form

























          X

























                X

                European, Middle East and UK

                Contrec Limited

                Unit G8, Navigation Close

                Lowfields Business Park

                Elland, West Yorkshire

                HX5 9HB

                United Kingdom.

                +44 (0) 1422 829944 [email protected]

                Sales Director: Craig Naylor

                [email protected]

                Sales and general enquiries

                [email protected]

                Marketing: Lucy Wood

                [email protected]
                X

                Americas and Canada Sales

                Contrec USA

                916 Belcher Drive

                Pelham, Alabama, 35124

                United States.

                +1 205 685 3000 +1 205 685 3001 [email protected]
                X

                Australia and Asia Sales

                Contrec Systems Pty Ltd

                5 Norfolk Ave, Ringwood

                Melbourne, Victoria, 3134

                Australia.

                +61 (0) 0413 505 114 [email protected]

                Managing Director: Paul Chaston

                [email protected]
                ©2025 Contrec Limited - This website was designed and developed by LASERLINES Creative Limited

                Whilst every effort has been made to ensure the accuracy of the information/material contained on our web site, we cannot guarantee that it is free from errors or omissions.