OUR PRODUCTS ABOUT CONTREC MEET OUR TEAM NEWS CONTACT

Controllers by Series

100 Series 200 Series 400 Series 515 Series Trac-50 LoadPro® Accessories

Products by Functionality

Accessories

Batch Controllers

- Batch/Additive Controllers

- Batch/Flow Controllers

- Batch/Ratio Controllers

- Standard Batch Controllers

Density Computers

Flow Computers

- General Flow Computers

- General Gas Flow Computers

- Heat Calculators

- Mass Flow Computers

- Master Proving Flow Computers

- Natural Gas Flow Computers

- Open Channel Flow Computers

- Special Application Flow Computers

- Steam Flow Computers

Flow Rate Totalisers

- Hazardous Area Flow Rate Totalisers

- Safe Area Flow Rate Totalisers

Level IndicatorsLoad ControllersSite AccessTruck Registers

Products by Industries

AviationBarge & Rail TransportBiofuels ProductionChemical & PharmaceuticalFood & BeverageFuel DepotGas Storage & DistributionMineral MiningNuclearOil & GasOil RefineryPower/EnergyWater & Waste Treatment

515-GN05 – DP Meter (AGA-8), Natural Gas (AGA-8)

Natural Gas Flow Computer (AGA – 8) – DP Meter (AGA – 3)

The 515-GN05 application is a natural gas flow computer. This application measures the volume, mass and gross heat content of natural gas. The instrument uses single or stacked differential pressure inputs, as well as temperature and pressure sensor inputs.

This natural gas flow computer calculates the flow according to AGA-3 differential pressure equations. The flow calculations incorporate the conditions at which the flowmeter was calibrated and accurately account for thermal expansion effect.

The AGA-8 Detail Characterization Method is used to obtain accurate values of density and compressibility factors for the flow calculations. For other gas properties, such as viscosity and isentropic exponent, the AGA-3 recommended values are used.

Calculations

The gas density and compressibility factor calculations are based on the AGA-8 equations. The calculations are valid for the region:
• -130°C < t < 400°C P < 280MPa
• -200°F < t < 760°F P < 40000psia

Formulas:
• volume flow =Mflow/ρflow
• corrected flow = Mflow/ρ ref
• Heat flow = Mflow•Hm

Where:
• Mflow = mass flow
• ρflow = density at flow conditions
• ρ ref = density at reference conditions
• Hm = mass gross heating value

Displayed Information

The front panel display shows the current values of the input variables and the results of the calculations. A list of the variables for this application and their type (total or rate) is shown at the end of this document.

The instrument can be supplied with a real-time clock for data logging of over 1000 entries of the variables as displayed on the main menu.

Isolated Outputs

The opto-isolated outputs can re-transmit any main menu variable. The type of output is determined by the nature of the assigned variable. Totals are output as pulses and rates are output as 4-20 mA signals. One output is standard, a second output is available as an option.

Relay Outputs

The relay alarms can be assigned to any of the main menu variables of a rate type. The alarms can be fully configured including hysteresis. Two relays are standard with additional two relays available as an option. All set-up parameters, totals and logged data are stored in non-volatile memory with at least 30 years retention.

Software Configuration The instrument can be further tailored to suit specific application needs including units of measurement, custom tags, second language or access levels. A distributor can configure these requirements before delivery.
Instrument parameters including units of measurement can be programmed in the field, according to the user access levels assigned to parameters by the distributor.

Temperature and Pressure Input Types

Temperature sensor input(s) can be either PT100, PT500, 4-20 mA, 0-5 V or 1-5V signals. Pressure sensor input(s) can be either 4-20 mA, 0-5 V or 1-5V signals

For more information on other products please click below.

Back to Product Index Back to Product Index Back to Product Index

Related Accessories

Back to Index

Request a Quote/Enquiry








    Features

    Tailored for differential pressure meters with single or stacked transmitters
    AGA-8 Natural Gas Detail Characterisation Method calculations for gas compositions with up to 21 components
    Gross heating values calculated to ISO 6976:1995 and GPA Standard 2172-96
    AGA-3 DP flow calculations
    Allows for non-linear correction
    Selection of second language and user tags
    RTC logging with over 1000 entries
    Infra-red communications port on front panel
    Pulse width and scaling of pulse output
    4-20mA retransmission
    Selectable protocols on serial ports including Modbus RTU and printer output
    Front panel adjustment of 8-24V DC output voltage
    Backlit Display
    LCD Backup

    Typical plant diagram

    Downloads

    Compare with similar products

    X

    Worldwide Sales Offices

    European, Middle East and UK

    +44 (0) 1422 829944

    [email protected]

    Sales Director: Craig Naylor – [email protected]

    Sales and General Enquiries – [email protected]

    Marketing: Lucy Wood – [email protected]

    Americas and Canada Sales

    +1 205 685 3000

    +1 205 685 3001

    [email protected]

    General Enquiries – [email protected]

    Australia and Asia Sales

    +61 (0) 0413 505 114

    [email protected]

    Managing Director: Paul Chaston – [email protected]

    Enquiry Form

























          X

























                X

                European, Middle East and UK

                Contrec Limited

                Unit G8, Navigation Close

                Lowfields Business Park

                Elland, West Yorkshire

                HX5 9HB

                United Kingdom.

                +44 (0) 1422 829944 [email protected]

                Sales Director: Craig Naylor

                [email protected]

                Sales and general enquiries

                [email protected]

                Marketing: Lucy Wood

                [email protected]
                X

                Americas and Canada Sales

                Contrec USA

                916 Belcher Drive

                Pelham, Alabama, 35124

                United States.

                +1 205 685 3000 +1 205 685 3001 [email protected]
                X

                Australia and Asia Sales

                Contrec Systems Pty Ltd

                5 Norfolk Ave, Ringwood

                Melbourne, Victoria, 3134

                Australia.

                +61 (0) 0413 505 114 [email protected]

                Managing Director: Paul Chaston

                [email protected]
                ©2025 Contrec Limited - This website was designed and developed by LASERLINES Creative Limited

                Whilst every effort has been made to ensure the accuracy of the information/material contained on our web site, we cannot guarantee that it is free from errors or omissions.