For more information on other products please click below.
Back to Product Index Back to Product Index Back to Product Index
The 515-FP01 application measures the flow and consumption of petroleum fluid. The two-channel frequency flow input enables the instrument to calculate the “delta” net volume that is used by a consuming device.
Each channel has an analog temperature input that allows for volume correction to reference conditions. It is expected that the feed flow will be greater than the return flow. An exception will be raised if negative flow is detected.
The instrument can be used to measure a range of crude and refined petroleum fluids included gasoline, jet fuels, heating oils, diesels, lube oils and LPGs.
Calculations
The volume total and flowrate are derived from accurately measured frequency and the number of recieved pulses:
• volume = pulses/k-factor
• volume flow = frequency/k-factor
• consumption volume = feed – return
The volume correction calculations are based on the ASTM D1250-04 and API Table 54 standard for the following products:
• Crude Oils
• Lube Oils
• Refined Products
• Light Hydrocarbon Liquids (LPG)
Volume correction for other fluids can be calculated by the following means:
• General Coefficient of Expansion
• Reprogrammed User Table

Related Accessories

Software – Program Manager (Download)

Software – DataMod Tool

IP65 – Stainless Steel (Custom)

IP66 – Weatherproof Enclosure

PR-00 – Thermal Panel Printer

PR-01 – Roll Printer (Panel Mount Impact)

PR-02 – Desktop 24VDC or 240VAC

PR-03 – Desktop 240VAC 80 Col

PR-04 – Thermal Ticket Printer