Trac 40
The 405 Flow Computer can handle a wide range of flow applications, where high accuracy and flexibility are required


Trac – 40 Electronic Truck Register

Overview

In truck applications where electronic registers must be able to operate in adverse conditions, the Trac -40 offers an economical solution for flow measurement and control.

Designed to operate with turbine, positive displacement or coriolis flowmeters, the Trac -40 meets the requirements for custody transfer of liquids throughout the world.

Based on Contrec’s 400 Series instruments, the Trac- 40 includes:

  • Rugged facia and switches
  • Robust Connectors
  • Backlit Display
  • Mounting Feet
  • Conformal coated electronic assemblies similar to those used by the military

Specifically designed for truck installations, the Trac- 40 is a register that will survive in the toughest of environments for electronics.

Preset or Start/Stop Mode

The Trac -40 can be programmed to operate as either a Preset system where the required quantity is entered prior to a delivery, or as a Start/Stop system where an unspecified  quantity and be delivered.

Both modes have relay outputs which can be used to control pumps and valves.

Custody Transfer Approval

The Trac -40 includes a dual pulse integrity check of the input signal and temperature compensation to API Tables as required for custody transfer.

Temperature compensation is selectable to include compensation for general petroleums, LPG or other products. If temperature compensation is not required it can be disabled.

Features

  • Rugged
  • Temperature Compensation
  • Complies with international metrology standards
  • Prints delivery tickets
  • Nema 4X or IP65 enclosure

Applications

  • Petroleum tankers with metered deliveries
  • LPG Trucks
  • Aircraft refuelling
  • Anhydrous Ammonia
  • Chemical Trucks
  • Heating Oil Trucks

Truck Interlocks

Because the Trac- 40 is designed for truck applications, speacial features unique to truck applications are incorporated in to the system including:

  • A low frequency input cutoff which will ignore spurious flowmeter pulses which may be caused by pipe vibration as the vehicle travels between deliveries.
  • A transaction timeout which is incorporated into the software to prevent a partial delivery at one location and then a continued delivery at a second location  without resetting the register (termed “riding the ticket”).
  • Delivery totals continue to be displayed even if power is disconnected.
  • A printer integrity test which will signal an error message if there is a printer problem.
  • 12 Volt dc and 24 Volt dc operation

Communications

The Trac- 40 can operate in one of the following modes:

1.   Printer Only

Interfaces to an industry standard slip printer or standard line printers.

2.  On-Board Computer

With an order on-board computer transaction results can be uploaded to the         computer at the end of the delivery.

Specifications

Physical

Display

6 digit  (11.8mm high) backlit LCD with

automatic ranging

Keypad Buttons

Switches:

Four heavy duty switches

Weights and Measures Seal:

A program access switch located behind a screw on the rear facia, can be affixed with a lead seal to prevent tampering

Standard Enclosure

Dimensions:

144mm (5.7″) wide x 72mm (2.8″) high x 190mm (7.5″) deep. The connector backshells will extend the depth to 235mm (9.3″).

Material :

Anodised aluminium

Sealing:

IP65 (Nema 4X weatherproof

Weight:

1.5kg (approx)

Cable Connection:

Four “D” style connectors

Explosionproof Enclosure

Dimensions:

285mm (11.2″) wide x 287mm (11.3″) high x 231mm (9.1″) deep. The connector backshells will extend the depth to 235mm (9.3″).

Approvals:

Cenelec and CSA (NRTL/C) applied for.

Operational

Power Requirements

12 Vdc to 28 Vdc. 3 watt maximum 130mA typical current (no options)

Operating Temperature

0 to 60ºC

Communications

Dual RS232 shared port.

Inputs and Outputs

Flow Inputs

Input Frequency:

0-10kHz with single pulse input

0-2kHz with dual (quadrature) input

Note: Dual pulse is for pulse verification only

and does not detect reverse flow

Pulse Intergrity

(Dual Pulse Only)

If a pulse failure is detected the system will alarm and stop flow on that channel

Note: This is in accord with API Standards, Chapter 5, Section 5; AS2702 – 1984;

and ISO6551-1982

K-factor

Linear:

Single point 0.001 to 50000.0

Non Linear:

10 Points 0.001 to 50000.0

Temperature Inputs

Input Signal:

RTD (4-Wire)

Range:
LPG:

-45°C to 60°C (-49°C to 140°C)

Petroleum:

-100°C to 200°C (-148°C to 392°C)

General Liquids:

-273°C to 200°C (-459°C to 392°C)

Anhydrous Ammonia:

0°C to 40°C (32°F to 104°F)

Input Circuit:

12 bit A/D converter

Correction:

To API Table 24B/54B for gasoline, diesel, jet fuel; Table 34/54 for LPG; and Table 24A/54A for crude oil.  Also correction for anhydrous ammonia is available

Valve Control Outputs

(dual Stage on/off)
Max Contact Voltage:

30 Vdc or 30 Vac

Max Current:

3A

Pulse Output

Pulse Width:

10 mSec

Max Frequency: 49 Hz

Important: Specifications are subject to change without notice.