><channel><title>Contrec Global</title> <atom:link href="http://www.contrec.co.uk/feed/" rel="self" type="application/rss+xml" /><link>http://www.contrec.co.uk</link> <description>Flow Metering Experts</description> <lastBuildDate>Wed, 22 Feb 2012 16:35:50 +0000</lastBuildDate> <language>en</language> <sy:updatePeriod>hourly</sy:updatePeriod> <sy:updateFrequency>1</sy:updateFrequency> <generator>http://wordpress.org/?v=3.2.1</generator> <item><title>515 &#8211; BF01</title><link>http://www.contrec.co.uk/55-bf01/</link> <comments>http://www.contrec.co.uk/55-bf01/#comments</comments> <pubDate>Fri, 15 Apr 2011 05:00:34 +0000</pubDate> <dc:creator>Nick</dc:creator> <category><![CDATA[515 Series]]></category> <category><![CDATA[Batch Controllers]]></category> <category><![CDATA[515 BF01]]></category> <category><![CDATA[backlit display]]></category> <category><![CDATA[backup check]]></category> <category><![CDATA[correct delivery]]></category> <category><![CDATA[date stamp]]></category> <category><![CDATA[dual stage]]></category> <category><![CDATA[error detection]]></category> <category><![CDATA[input variables]]></category> <category><![CDATA[loop control]]></category> <category><![CDATA[overflow error]]></category> <category><![CDATA[pi control]]></category> <category><![CDATA[preset value]]></category> <category><![CDATA[preset values]]></category> <category><![CDATA[printer output]]></category> <category><![CDATA[proportional valve]]></category> <category><![CDATA[rtu]]></category> <category><![CDATA[serial ports]]></category> <category><![CDATA[stage control]]></category> <category><![CDATA[valve closure]]></category> <category><![CDATA[valves and actuators]]></category> <category><![CDATA[volume flow]]></category><guid
isPermaLink="false">http://www.contrec.co.uk/?p=571</guid> <description><![CDATA[Overview Terminal Designations 515 BF01 Dimension Drawings 515  Specifications Ordering Information Product Codes &#160; Product Manual Download]]></description> <content:encoded><![CDATA[<h2>Overview</h2><div
class="one_third"></p><p>The 515 BF01 application is a batching controller for delivery of preset quantities at preset flowrates using a volumetric frequency input. Batch control can operate in preset or on-off modes, while flow control can be set to local (manual) or PI loop mode.</p><p>This application provides the operator with clear local readout including flowrate deviation and can be controlled via communications in more automated systems. There is quick access to commonly used preset values directly from the front panel if access has been authorized.</p><p>The PI control of the process flow is via a 4-20mA proportional valve or pump controller. It has integral wind- up protection, a deadband, output hold and ramp time that can be programmed to reduce wear on valves and actuators and provide for bumpless operation.</p><p></div><div
class="one_third"></p><h4>Calculations</h4><p>The total and flowrate are derived from accurately measured frequency and the number of received pulses.</p><p><em>volume = pulses / k-factor</em></p><p><em>volume flow = frequency / k-factor</em></p><p>Automatic overrun compensation calculates the new valve closure point to ensure correct delivery by averageing the overrun amount from the last three complete batches.</p><p>The overrun compensation value is valid for a new preset value provided the stored overrun is less than 20% of the new preset.</p><p></div><div
class="one_third last"></p><h3>Features at a glance</h3><p></p><ul
class="check_list"><li>Tailored for volumetric frequency flow input</li><li>Single or Dual stage control</li><li>Preset or manual On-Off modes</li><li>Easy access to batch and flow rate presets</li><li>No-flow, leakage and overflow error detection</li><li>Remote RUN/STOP/RESET</li><li>Allows for permissive with prompt</li><li>Uses PI Loop Control</li><li>Allows for non-linear correction</li><li>Storage of 1000 transactions with time and date stamp</li><li>Selection of second language and user tags</li><li>Selectable protocols on serial ports including Modbus RTU and Printer output</li><li>Backlit display with LCD backup</li></ul><p></p><p></div><div
class="clearboth"></div><p><img
class="alignnone size-full wp-image-639" title="BF01-diagram" src="http://www.contrec.co.uk/wp-content/uploads/2011/04/BF01-diagram.jpg" alt="BF01 batch/flow computer diagram" width="910" height="264" /></p><div
class="one_half"></p><h4>Displayed Information</h4><p>The front panel display shows the current values of the input variables and the results of the calculations. A list of the variables for this application and their type (total or rate) is shown at the end of this document.</p><p>The instrument can be supplied with a real-time clock for storage of up to 100 transactions with time and date stamps.</p><h4>Communications</h4><p>There are three communication ports available as follows:</p><p></p><ul
class="arrow_list"><li>RS-232 port (standard)</li><li>RS-485 port (advanced option)</li><li>Infra-red port (on front panel)</li></ul><p></p><p>The ports are available for remote data reading, printouts and for initial application loading of the instrument.</p><h4>Isolated Outputs</h4><p>The opto-isolated outputs can retransmit any main menu variable. The type of output is determined by the nature of the assigned variable. Totals are output as pulses and rates are output as 4-20 mA signals. One output is standard, a second output is available as an option.</p><p></div><div
class="one_half last"></p><h4>Relay Outputs</h4><p>The relay outputs 1 and 2 are used to control the flow of product for each delivery. These contacts are normally open and can be used to drive external relays, valves, pump circuits etc.</p><h4>Software Configuration</h4><p>The instrument can be further tailored to suit specific application needs including units of measurement, custom tags, second language or access levels. A distributor can configure these requirements before delivery.</p><p>Instrument parameters including units of measurement can be programmed in the field, according to the user access levels assigned to parameters by the distributor.</p><p>All set-up parameters, totals and logged data are stored in non-volatile memory with at least 30 years retention.</p><p>&nbsp;</p><p><img
class="alignnone size-full wp-image-549" title="500-batch-computer-side" src="http://www.contrec.co.uk/wp-content/uploads/2011/04/500-batch-computer-side.jpg" alt="500 series batch computer" width="456" height="257" /></p><p></div><div
class="clearboth"></div><div
class="divider top"><a
href="#">Top</a></div><h2>Terminal Designations</h2><table
id="wp-table-reloaded-id-167-no-1" class="wp-table-reloaded wp-table-reloaded-id-167"><thead><tr
class="row-1"><th
class="column-1">Terminal Label</th><th
class="column-2"></th><th
class="column-3"></th><th
class="column-4">Designation</th><th
class="column-5">Comment</th></tr></thead><tbody
class="row-hover"><tr
class="row-2"><td
class="column-1">1</td><td
class="column-2">FINP</td><td
class="column-3">1+</td><td
class="column-4">Frequency Input 1+</td><td
class="column-5">Volumetric flow Input</td></tr><tr
class="row-3"><td
class="column-1">3</td><td
class="column-2">SG</td><td
class="column-3">-</td><td
class="column-4">Signal Ground</td><td
class="column-5"></td></tr><tr
class="row-4"><td
class="column-1">15</td><td
class="column-2">Vo</td><td
class="column-3">+</td><td
class="column-4">8-24 volts DC output</td><td
class="column-5">Overload protected</td></tr><tr
class="row-5"><td
class="column-1">16</td><td
class="column-2">G</td><td
class="column-3">-</td><td
class="column-4">DC Ground</td><td
class="column-5"></td></tr><tr
class="row-6"><td
class="column-1">17</td><td
class="column-2">Vi</td><td
class="column-3">+</td><td
class="column-4">DC power input</td><td
class="column-5">DC power in 12-28V</td></tr><tr
class="row-7"><td
class="column-1">18</td><td
class="column-2">SH</td><td
class="column-3">E</td><td
class="column-4">Shield terminal</td><td
class="column-5"></td></tr><tr
class="row-8"><td
class="column-1">19</td><td
class="column-2">RS485</td><td
class="column-3">+</td><td
class="column-4">RS485 (+)</td><td
class="column-5">Advanced option</td></tr><tr
class="row-9"><td
class="column-1">20</td><td
class="column-2">RS485</td><td
class="column-3">-</td><td
class="column-4">RS485 (-)</td><td
class="column-5">Advanced option</td></tr><tr
class="row-10"><td
class="column-1">21</td><td
class="column-2">RS485</td><td
class="column-3">G</td><td
class="column-4">RS485 Ground</td><td
class="column-5">Advanced option</td></tr><tr
class="row-11"><td
class="column-1">22</td><td
class="column-2">LOGIC INPUTS</td><td
class="column-3">1+</td><td
class="column-4">Switch 1</td><td
class="column-5">Remote Run</td></tr><tr
class="row-12"><td
class="column-1">23</td><td
class="column-2">LOGIC INPUTS</td><td
class="column-3">2+</td><td
class="column-4">Switch 2</td><td
class="column-5">Remote Stop</td></tr><tr
class="row-13"><td
class="column-1">24</td><td
class="column-2">LOGIC INPUTS</td><td
class="column-3">3+</td><td
class="column-4">Switch 3</td><td
class="column-5">Remote Reset</td></tr><tr
class="row-14"><td
class="column-1">25</td><td
class="column-2">LOGIC INPUTS</td><td
class="column-3">4+</td><td
class="column-4">Switch 4</td><td
class="column-5">Permissive Input</td></tr><tr
class="row-15"><td
class="column-1">26</td><td
class="column-2">LOGIC INPUTS</td><td
class="column-3">C-</td><td
class="column-4">Signal ground</td><td
class="column-5"></td></tr><tr
class="row-16"><td
class="column-1">27</td><td
class="column-2">OUT 1</td><td
class="column-3">+</td><td
class="column-4">Output ch 1 (+)</td><td
class="column-5">Process control output</td></tr><tr
class="row-17"><td
class="column-1">28</td><td
class="column-2">OUT 1</td><td
class="column-3">-</td><td
class="column-4">Output ch 1 (-)</td><td
class="column-5">Process control output</td></tr><tr
class="row-18"><td
class="column-1">29</td><td
class="column-2">OUT 2</td><td
class="column-3">+</td><td
class="column-4">Output ch 2 (+)</td><td
class="column-5">Optional Output</td></tr><tr
class="row-19"><td
class="column-1">30</td><td
class="column-2">OUT 2</td><td
class="column-3">-</td><td
class="column-4">Output ch 2 (-)</td><td
class="column-5">Optional Ouput</td></tr><tr
class="row-20"><td
class="column-1">31</td><td
class="column-2">RELAYS</td><td
class="column-3">RC</td><td
class="column-4">Relay common</td><td
class="column-5"></td></tr><tr
class="row-21"><td
class="column-1">32</td><td
class="column-2">RELAYS</td><td
class="column-3">R1</td><td
class="column-4">Relay 1</td><td
class="column-5">Single stage control</td></tr><tr
class="row-22"><td
class="column-1">33</td><td
class="column-2">RELAYS</td><td
class="column-3">R2</td><td
class="column-4">Relay 2</td><td
class="column-5">Dual stage control</td></tr><tr
class="row-23"><td
class="column-1">34</td><td
class="column-2">RELAYS</td><td
class="column-3">R3</td><td
class="column-4">Relay 3</td><td
class="column-5">Advanced option</td></tr><tr
class="row-24"><td
class="column-1">35</td><td
class="column-2">RELAYS</td><td
class="column-3">R4</td><td
class="column-4">Relay 4</td><td
class="column-5">Advanced option</td></tr><tr
class="row-25"><td
class="column-1">E</td><td
class="column-2">AC MAINS</td><td
class="column-3">E</td><td
class="column-4">Mains ground</td><td
class="column-5">AC power in 95-135V or 190-260V</td></tr><tr
class="row-26"><td
class="column-1">N</td><td
class="column-2">AC MAINS</td><td
class="column-3">N</td><td
class="column-4">Mains neutral</td><td
class="column-5">AC power in 95-135V or 190-260V</td></tr><tr
class="row-27"><td
class="column-1">A</td><td
class="column-2">AC MAINS</td><td
class="column-3">A</td><td
class="column-4">Mains active</td><td
class="column-5">AC power in 95-135V or 190-260V</td></tr><tr
class="row-28"><td
class="column-1">RS232 port</td><td
class="column-2"></td><td
class="column-3">9-pin serial port</td><td
class="column-4"></td><td
class="column-5"></td></tr></tbody></table><div
class="divider top"><a
href="#">Top</a></div><h2>515 BF01 Dimension Drawings</h2><div
class="one_third"></p><h3>Part Number</h3><p>515.XXXXXX-BF01</p><p>See product codes to select required features</p><p>Default application software:</p><p>515-BF01-000000</p><p></div><div
class="two_third last"></p><h3><img
class="alignnone size-full wp-image-581" title="515-dimensional-drawings" src="http://www.contrec.co.uk/wp-content/uploads/2011/04/515-dimensional-drawings.gif" alt="515 batch/flow computer dimensional drawings" width="624" height="349" /></h3><p></div><div
class="clearboth"></div><div
class="divider top"><a
href="#">Top</a></div><h2>515  Specifications</h2><div
class="one_half"></p><h3><p
class="fancy_header"><span>Operating Environment</span></p></h3><h5>Temperature</h5><p>-20 °C to +60 °C (conformal coating)<br
/> +5 °C to +40 °C (no coating)</p><h5>Humidity</h5><p>0 to 95% non condensing (conformal coating)<br
/> 5% to 85% non condensing (no coating)</p><h5>Power Supply</h5><p>95&#8230;135 V AC or 190&#8230;260 V AC or<br
/> 12&#8230;28 V DC</p><h5>Consumption</h5><p>6W (typical)</p><h5>Protection</h5><p>Sealed to IP65 (Nema 4X) when panel mounted</p><h5>Dimensions</h5><p>147 mm (5.8&#8243;) width<br
/> 74 mm (2.9&#8243;) height<br
/> 167 mm (6.6&#8243;) depth</p><h3><p
class="fancy_header"><span>Display</span></p></h3><h5>Type</h5><p>Backlit LCD with 7-digit numeric display and 11-character alphanumeric display</p><h5>Digits</h5><p>15.5 mm (0.6&#8243;) high</p><h5>Characters</h5><p>6 mm (0.24&#8243;) high</p><h5>LCD Backup</h5><p>Last data visible for 15 min after power down</p><h5>Update Rate</h5><p>0.3 second</p><h3><p
class="fancy_header"><span>Non-volatile Memory</span></p></h3><h5>Retention</h5><p>&gt; 30 years</p><h5>Data Stored</h5><p>Setup, Totals and Logs</p><h3><p
class="fancy_header"><span>Approvals</span></p></h3><h5>Interference</h5><p><strong>CE</strong> compliance</p><h5>Enclosure</h5><p><strong> </strong>ATEX, FM, CSA and SAA approved enclosures available for hazardous areas</p><h3><p
class="fancy_header"><span>Real Time Clock (Optional)</span></p></h3><h5>Battery Type</h5><p>3 volts Lithium button cell (CR2032)</p><h5>Battery Life</h5><p>5 years (typical)</p><h3><p
class="fancy_header"><span>Frequency Input (General)</span></p></h3><h5>Range</h5><p>0 to 10 kHz</p><h5>Over Voltage</h5><p>30 V maximum</p><h5>Update Time</h5><p>0.3 sec</p><h5>Cutoff Frequency</h5><p>Programmable</p><h5>Configuration</h5><p>Pulse, coil or NPS input</p><h5>Non-linearity</h5><p>Up to 10 correction points</p><h3><p
class="fancy_header"><span>Pulse</span></p></h3><h5>Signal Type</h5><p>CMOS, TTL, open collector, reed switch</p><h5>Threshold</h5><p>1.3 volts</p><p></div><div
class="one_half last"></p><h3><p
class="fancy_header"><span>Coil</span></p></h3><h5>Signal Type</h5><p>Turbine and sine wave</p><h5>Sensitivity</h5><p><strong> </strong>15 mV p-p minimum</p><h3><p
class="fancy_header"><span>NPS</span></p></h3><h5>Signal Type</h5><p>NPS sensor to Namur standard</p><h3><p
class="fancy_header"><span>Logic Inputs</span></p></h3><h5>Signal Type</h5><p><strong> </strong><strong> </strong>CMOS, TTL, open collector, reed switch</p><h5>Overvoltage</h5><p><strong> </strong>30V maximum</p><h3><p
class="fancy_header"><span>Relay Output</span></p></h3><h5>No. of Outputs</h5><p>2 relays plus 2 optional relays</p><h5>Voltage</h5><p>250 volts AC, 30 volts DC maximum (solid state relays use AC only)</p><h5>Current</h5><p>3 A maximum</p><h3><p
class="fancy_header"><span>Communication Ports</span></p></h3><h5>Ports</h5><p>RS-232 port<br
/> RS-485 port (optional)<br
/> Infra-red port</p><h5>Baud Rate</h5><p>2400 to 19200 baud</p><h5>Parity</h5><p>Odd, even or none</p><h5>Stop Bits</h5><p>1 or 2</p><h5>Protocols</h5><p>ASCII, Modbus RTU, Printer</p><h3><p
class="fancy_header"><span>Transducer Supply</span></p></h3><h5>Voltage</h5><p>8 to 24 volts DC, programmable</p><h5>Current</h5><p>70 mA @ 24 V, 120 mA @ 12 V maximum</p><h5>Protection</h5><p>Power limited output</p><h3><p
class="fancy_header"><span>Isolated Output</span></p></h3><h5>No. of Outputs</h5><p><strong> </strong>1 configurable output (plus 1 optional)</p><h5>Configuration</h5><p>Pulse/Digital or 4-20 mA output</p><h3><p
class="fancy_header"><span>Pulse/Digital Output</span></p></h3><h5>Signal Type</h5><p>Open collector</p><h5>Switching</h5><p><strong> </strong>200 mA, 30 volts DC maximum</p><h5>Saturation</h5><p>0.8 volts maximum</p><h5>Pulse Width</h5><p>Programmable: 10 , 20, 50, 100, 200 or 500ms</p><h3><p
class="fancy_header"><span>4-20mA Output (Optional)</span></p></h3><h5>Supply</h5><p>9 to 30 volts DC external</p><h5>Resolution</h5><p>0.05% full scale</p><h5>Accuracy</h5><p>0.05% full scale (20°C)<br
/> 0.1% (full temperature range, typical)</p><p><strong>Important:</strong> Specifications are subject to change without notice.</p><p></div><div
class="clearboth"></div><div
class="divider top"><a
href="#">Top</a></div><h2>Ordering Information</h2><h3>Product Codes</h3><table
id="wp-table-reloaded-id-169-no-1" class="wp-table-reloaded wp-table-reloaded-id-169"><thead><tr
class="row-1 odd"><th
class="column-1">Model</th><th
colspan="7" class="column-2 colspan-7">Supplementary Code</th><th
class="column-9">Description</th></tr></thead><tbody><tr
class="row-2 even"><td
class="column-1">515</td><td
class="column-2"></td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7">-</td><td
class="column-8">BF01</td><td
class="column-9"></td></tr><tr
class="row-3 odd"><td
class="column-1">Enclosure</td><td
class="column-2">1</td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Panel mount enclosure</td></tr><tr
class="row-4 even"><td
class="column-1">Enclosure</td><td
class="column-2">2</td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Field mount enclosure (not yet available)</td></tr><tr
class="row-5 odd"><td
class="column-1">Enclosure</td><td
class="column-2">3/5</td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Explosion proof Ex410 with metric glands (5 specifies heater version)</td></tr><tr
class="row-6 even"><td
class="column-1">Enclosure</td><td
class="column-2">4/6</td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Explosion proof Ex410 with NPT glands (6 specifies heater version)</td></tr><tr
class="row-7 odd"><td
colspan="2" class="column-1 colspan-2">Output Options</td><td
class="column-3">0</td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">4 logic inputs, 1 isolated output, 2 relays (only relay type 1 is available), RS232 (DB9) communication port</td></tr><tr
class="row-8 even"><td
colspan="2" class="column-1 colspan-2">Output Options</td><td
class="column-3">1</td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">4 logic inputs, 2 isolated outputs, 4 relays, real-time clock data logging, RS232 (DB9) and RS485 communication ports</td></tr><tr
class="row-9 odd"><td
colspan="2" class="column-1 colspan-2">Output Options</td><td
class="column-3">2/3</td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">4 logic inputs, 2 isolated outputs, 4 relays, real-time clock data logging, RS232 (DB9) and Ethernet/RF communication ports (not yet available)</td></tr><tr
class="row-10 even"><td
colspan="3" class="column-1 colspan-3">Relay Type</td><td
class="column-4">1</td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Electromechanical relays only</td></tr><tr
class="row-11 odd"><td
colspan="3" class="column-1 colspan-3">Relay Type</td><td
class="column-4">2</td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">2 electromechanical and 2 solid state relays</td></tr><tr
class="row-12 even"><td
colspan="3" class="column-1 colspan-3">Relay Type</td><td
class="column-4">3</td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Solid state relays only (not yet available)</td></tr><tr
class="row-13 odd"><td
class="column-1">Power Supply</td><td
class="column-2"></td><td
colspan="2" class="column-3 colspan-2"></td><td
class="column-5">E</td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">For 220/240 VAC</td></tr><tr
class="row-14 even"><td
class="column-1">Power Supply</td><td
class="column-2"></td><td
colspan="2" class="column-3 colspan-2"></td><td
class="column-5">A</td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">For 110/120 VAC</td></tr><tr
class="row-15 odd"><td
class="column-1">Power Supply</td><td
class="column-2"></td><td
colspan="2" class="column-3 colspan-2"></td><td
class="column-5">D</td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">For DC power only 12-28 VDC</td></tr><tr
class="row-16 even"><td
class="column-1">Display Panel Options</td><td
class="column-2"></td><td
class="column-3"></td><td
colspan="2" class="column-4 colspan-2"></td><td
class="column-6">F</td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Fully optioned (with backlight, LCD backup and Infra-Red comms port)</td></tr><tr
class="row-17 odd"><td
class="column-1">PCB Protection</td><td
class="column-2"></td><td
class="column-3"></td><td
class="column-4"></td><td
colspan="2" class="column-5 colspan-2"></td><td
class="column-7">C</td><td
class="column-8"></td><td
class="column-9">Conformal coating - required for maximum environmental operating range. Recommended to avoid damage from moisture and corrosion.</td></tr><tr
class="row-18 even"><td
class="column-1">PCB Protection</td><td
class="column-2"></td><td
class="column-3"></td><td
class="column-4"></td><td
colspan="2" class="column-5 colspan-2"></td><td
class="column-7">N</td><td
class="column-8"></td><td
class="column-9">None - suitable for IEC standard 654-1 Climatic Conditions up to Class B2 (Heated and/or cooled enclosed locations)</td></tr><tr
class="row-19 odd"><td
class="column-1">Application Pack Number</td><td
class="column-2"></td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8">BF01</td><td
class="column-9">Defines the application software to be loaded into the instrument</td></tr></tbody></table><div
class="divider top"><a
href="#">Top</a></div><div
class="one_half"></p><h3>Main Menu Variables</h3><p><table
id="wp-table-reloaded-id-170-no-1" class="wp-table-reloaded wp-table-reloaded-id-170"><thead><tr
class="row-1 odd"><th
class="column-1">Main Menu Variables</th><th
class="column-2">Default Units</th><th
class="column-3">Preferred Units</th><th
class="column-4">Variable Type</th></tr></thead><tbody><tr
class="row-2 even"><td
class="column-1">Volume</td><td
class="column-2">Ltr</td><td
class="column-3"></td><td
class="column-4">Total</td></tr><tr
class="row-3 odd"><td
class="column-1">Volume Flowrate</td><td
class="column-2">L/min</td><td
class="column-3"></td><td
class="column-4">Rate</td></tr><tr
class="row-4 even"><td
class="column-1">Control Output</td><td
class="column-2">%</td><td
class="column-3">- - -</td><td
class="column-4">Rate</td></tr><tr
class="row-5 odd"><td
class="column-1">Flowrate Deviation</td><td
class="column-2">%</td><td
class="column-3"></td><td
class="column-4">Rate</td></tr></tbody></table></p><p>Please specify the preferred units of measurement.</p><p></div><div
class="one_half last"></div><div
class="clearboth"></div><p><img
class="size-full wp-image-446 alignnone" title="500-batch-enclosure" src="http://www.contrec.co.uk/wp-content/uploads/2011/04/500-batch-enclosure.jpg" alt="500 Series in Ex410 Enclosure" width="456" height="441" /></p><div
class="divider top"><a
href="#">Top</a></div><p>&nbsp;</p><h2>Product Manual Download</h2><div
class="download_box"><a
title="Product Manual Download" href="http://www.contrec.co.uk/wp-content/uploads/2011/09/515-BF01-OM.pdf" target="_blank">Click here to download the 515 BF01 product manual</a></div> ]]></content:encoded> <wfw:commentRss>http://www.contrec.co.uk/55-bf01/feed/</wfw:commentRss> <slash:comments>0</slash:comments> </item> <item><title>515 &#8211; BF02</title><link>http://www.contrec.co.uk/515-bf02/</link> <comments>http://www.contrec.co.uk/515-bf02/#comments</comments> <pubDate>Sat, 16 Apr 2011 07:47:02 +0000</pubDate> <dc:creator>Nick</dc:creator> <category><![CDATA[515 Series]]></category> <category><![CDATA[Batch Controllers]]></category> <category><![CDATA[515 BF02]]></category> <category><![CDATA[analog input]]></category> <category><![CDATA[backlit display]]></category> <category><![CDATA[backup check]]></category> <category><![CDATA[batch control]]></category> <category><![CDATA[correct delivery]]></category> <category><![CDATA[dual stage]]></category> <category><![CDATA[flow controller]]></category> <category><![CDATA[loop control]]></category> <category><![CDATA[loop mode]]></category> <category><![CDATA[mass flow]]></category> <category><![CDATA[overflow error]]></category> <category><![CDATA[pi control]]></category> <category><![CDATA[preset value]]></category> <category><![CDATA[printer output]]></category> <category><![CDATA[proportional valve]]></category> <category><![CDATA[rtu]]></category> <category><![CDATA[serial ports]]></category> <category><![CDATA[stage control]]></category> <category><![CDATA[valve closure]]></category> <category><![CDATA[valves and actuators]]></category><guid
isPermaLink="false">http://www.contrec.co.uk/?p=651</guid> <description><![CDATA[Overview Terminal Designations 515 BF02 Dimension Drawings 515  Specifications Ordering Information Product Codes Product Manual Download]]></description> <content:encoded><![CDATA[<h2>Overview</h2><div
class="one_third"></p><p>The 515 BF02 application is a batching flow controller for delivery of preset quantities at preset flowrates using a volumetric analog input. Batch control can operate in preset or on-off modes, while flow control can be set to local manual) or PI loop mode.</p><p>This application provides the operator with clear local readout including flowrate deviation and can be controlled via communications in more automated systems. There is quick access to commonly used preset values directly from the front panel if access has been authorized.</p><p>The PI control of the process flow is via a 4-20mA proportional valve or pump controller. It has integral wind- up protection, a deadband, output hold and ramp time that can be programmed to reduce wear on valves and actuators and provide for bumpless operation.</p><p></div><div
class="one_third"></p><h4>Calculations</h4><p>To derive the flow rate, the analog input is normalised to a value (A) between 0 and 1.</p><p><em>mass flow = (M</em><em><sub>f</sub> </em><em>max &#8211; M</em><em><sub>f</sub> </em><em>m</em><em>i</em><em>n</em><em>)A + M</em><em><sub>f</sub> </em><em>min mass </em>= ∫( <em>ma</em><em>ssflo</em><em>w </em>× Δ<em>t </em>)</p><p>Automatic overrun compensation calculates the new valve closure point to ensure correct delivery by averageing the overrun amount from the last three complete batches.</p><p>The overrun compensation value is valid for a new preset value provided the stored overrun is less than 20% of the new preset.</p><p></div><div
class="one_third last"></p><h3>Features at a glance</h3><p></p><ul
class="check_list"><li>Tailored for volumetric frequency flow input</li><li>Single or Dual stage control</li><li>Preset or manual On-Off modes</li><li>Easy access to batch and flow rate presets</li><li>No-flow, leakage and overflow error detection</li><li>Remote RUN/STOP/RESET</li><li>Allows for permissive with prompt</li><li>Uses PI Loop Control</li><li>Allows for non-linear correction</li><li>Storage of 1000 transactions with time and date stamp</li><li>Selection of second language and user tags</li><li>Selectable protocols on serial ports including Modbus RTU and Printer output</li><li>Backlit display with LCD backup</li></ul><p></p><p></div><div
class="clearboth"></div><p><img
class="alignnone size-full wp-image-640" title="BF02-diagram" src="http://www.contrec.co.uk/wp-content/uploads/2011/04/BF02-diagram.jpg" alt="BF02 batch/flow computer diagram" width="910" height="264" /></p><div
class="divider top"><a
href="#">Top</a></div><div
class="one_half"></p><h4>Displayed Information</h4><p>The front panel display shows the current values of the input variables and the results of the calculations. A list of the variables for this application and their type (total or rate) is shown at the end of this document.</p><p>The instrument can be supplied with a real-time clock for storage of up to 100 transactions with time and date stamps.</p><h4>Communications</h4><p>There are three communication ports available as follows:</p><p></p><ul
class="arrow_list"><li>RS-232 port (standard)</li><li>RS-485 port (advanced option)</li><li>Infra-red port (on front panel)</li></ul><p></p><p>The ports are available for remote data reading, printouts and for initial application loading of the instrument.</p><h4>Isolated Outputs</h4><p>The opto-isolated outputs can retransmit any main menu variable. The type of output is determined by the nature of the assigned variable. Totals are output as pulses and rates are output as 4-20 mA signals. One output is standard, a second output is available as an option.</p><p></div><div
class="one_half last"></p><h4>Relay Outputs</h4><p>The relay outputs 1 and 2 are used to control the flow of product for each delivery. These contacts are normally open and can be used to drive external relays, valves, pump circuits etc.</p><h4>Software Configuration</h4><p>The instrument can be further tailored to suit specific application needs including units of measurement, custom tags, second language or access levels. A distributor can configure these requirements before delivery.</p><p>Instrument parameters including units of measurement can be programmed in the field, according to the user access levels assigned to parameters by the distributor.</p><p>All set-up parameters, totals and logged data are stored in non-volatile memory with at least 30 years retention.</p><p>&nbsp;</p><p><img
class="alignnone size-full wp-image-549" title="500-batch-computer-side" src="http://www.contrec.co.uk/wp-content/uploads/2011/04/500-batch-computer-side.jpg" alt="500 series batch computer" width="456" height="257" /></p><p></div><div
class="clearboth"></div><div
class="divider top"><a
href="#">Top</a></div><h2>Terminal Designations</h2><table
id="wp-table-reloaded-id-41-no-1" class="wp-table-reloaded wp-table-reloaded-id-41"><thead><tr
class="row-1 odd"><th
colspan="3" class="column-1 colspan-3">Terminal Label</th><th
class="column-4">Designation</th><th
class="column-5">Comment</th></tr></thead><tbody><tr
class="row-2 even"><td
class="column-1">3</td><td
class="column-2">SG</td><td
class="column-3">-</td><td
class="column-4">Signal ground</td><td
class="column-5"></td></tr><tr
class="row-3 odd"><td
class="column-1">11</td><td
class="column-2">AINP3</td><td
class="column-3">+</td><td
class="column-4">Analog input ch 3 (+)</td><td
class="column-5">Main or low flow input</td></tr><tr
class="row-4 even"><td
class="column-1">12</td><td
class="column-2">AINP3</td><td
class="column-3">-</td><td
class="column-4">Analog input ch 3 (-)</td><td
class="column-5">Main or low flow input</td></tr><tr
class="row-5 odd"><td
class="column-1">13</td><td
class="column-2">AINP4</td><td
class="column-3">+</td><td
class="column-4">Analog input ch 4 (+)</td><td
class="column-5">High flow stacked input</td></tr><tr
class="row-6 even"><td
class="column-1">14</td><td
class="column-2">AINP4</td><td
class="column-3">-</td><td
class="column-4">Analog input ch 4 (-)</td><td
class="column-5">High flow stacked input</td></tr><tr
class="row-7 odd"><td
class="column-1">15</td><td
class="column-2">Vo</td><td
class="column-3">+</td><td
class="column-4">8-24 volts DC output</td><td
class="column-5">Overload protected</td></tr><tr
class="row-8 even"><td
class="column-1">16</td><td
class="column-2">G</td><td
class="column-3">-</td><td
class="column-4">DC Ground</td><td
class="column-5"></td></tr><tr
class="row-9 odd"><td
class="column-1">17</td><td
class="column-2">Vi</td><td
class="column-3">+</td><td
class="column-4">DC power input</td><td
class="column-5">DC power in 12-28V</td></tr><tr
class="row-10 even"><td
class="column-1">18</td><td
class="column-2">SH</td><td
class="column-3">E</td><td
class="column-4">Shield Terminal</td><td
class="column-5"></td></tr><tr
class="row-11 odd"><td
class="column-1">19</td><td
class="column-2">RS485</td><td
class="column-3">+</td><td
class="column-4">RS485(+)</td><td
class="column-5">Advanced option</td></tr><tr
class="row-12 even"><td
class="column-1">20</td><td
class="column-2">RS485</td><td
class="column-3">-</td><td
class="column-4">RS485(+)</td><td
class="column-5">Advanced option</td></tr><tr
class="row-13 odd"><td
class="column-1">21</td><td
class="column-2">RS485</td><td
class="column-3">G</td><td
class="column-4">RS485 ground</td><td
class="column-5">Advanced option</td></tr><tr
class="row-14 even"><td
class="column-1">22</td><td
class="column-2">Logic Inputs</td><td
class="column-3">1+</td><td
class="column-4">Switch 1</td><td
class="column-5">Remote Run</td></tr><tr
class="row-15 odd"><td
class="column-1">23</td><td
class="column-2">Logic Inputs</td><td
class="column-3">2+</td><td
class="column-4">Switch 2</td><td
class="column-5">Remote Stop</td></tr><tr
class="row-16 even"><td
class="column-1">24</td><td
class="column-2">Logic Inputs</td><td
class="column-3">3+</td><td
class="column-4">Switch 3</td><td
class="column-5">Remote reset</td></tr><tr
class="row-17 odd"><td
class="column-1">25</td><td
class="column-2">Logic Inputs</td><td
class="column-3">4+</td><td
class="column-4">Switch 4</td><td
class="column-5">Permissive Input</td></tr><tr
class="row-18 even"><td
class="column-1">26</td><td
class="column-2">Logic Inputs</td><td
class="column-3">C-</td><td
class="column-4">Signal ground</td><td
class="column-5"></td></tr><tr
class="row-19 odd"><td
class="column-1">27</td><td
class="column-2">Out 1</td><td
class="column-3">+</td><td
class="column-4">Output ch 1 (+)</td><td
class="column-5">Process control output</td></tr><tr
class="row-20 even"><td
class="column-1">28</td><td
class="column-2">Out 1</td><td
class="column-3">-</td><td
class="column-4">Output ch 1 (-)</td><td
class="column-5">Process control output</td></tr><tr
class="row-21 odd"><td
class="column-1">29</td><td
class="column-2">Out 2</td><td
class="column-3">+</td><td
class="column-4">Output ch 2 (+)</td><td
class="column-5">Advanced Option</td></tr><tr
class="row-22 even"><td
class="column-1">30</td><td
class="column-2">Out 2</td><td
class="column-3">-</td><td
class="column-4">Output ch 2 (-)</td><td
class="column-5">Advanced Option</td></tr><tr
class="row-23 odd"><td
class="column-1">31</td><td
class="column-2">RELAYS</td><td
class="column-3">RC</td><td
class="column-4">Relay Common</td><td
class="column-5"></td></tr><tr
class="row-24 even"><td
class="column-1">32</td><td
class="column-2">RELAYS</td><td
class="column-3">R1</td><td
class="column-4">Relay 1</td><td
class="column-5">Single Stage Control</td></tr><tr
class="row-25 odd"><td
class="column-1">33</td><td
class="column-2">RELAYS</td><td
class="column-3">R2</td><td
class="column-4">Relay 2</td><td
class="column-5">Dual Stage Control</td></tr><tr
class="row-26 even"><td
class="column-1">34</td><td
class="column-2">RELAYS</td><td
class="column-3">R3</td><td
class="column-4">Relay 3</td><td
class="column-5">Advanced Option</td></tr><tr
class="row-27 odd"><td
class="column-1">35</td><td
class="column-2">RELAYS</td><td
class="column-3">R4</td><td
class="column-4">Relay 4</td><td
class="column-5">Advanced Option</td></tr><tr
class="row-28 even"><td
class="column-1">E</td><td
class="column-2">AC MAINS</td><td
class="column-3">E</td><td
class="column-4">Mains ground</td><td
class="column-5">AC power in 95-135 V<br
/> or 190-260 V</td></tr><tr
class="row-29 odd"><td
class="column-1">N</td><td
class="column-2">AC MAINS</td><td
class="column-3">N</td><td
class="column-4">Mains neutral</td><td
class="column-5">AC power in 95-135 V<br
/> or 190-260 V</td></tr><tr
class="row-30 even"><td
class="column-1">A</td><td
class="column-2">AC MAINS</td><td
class="column-3">A</td><td
class="column-4">Mains active</td><td
class="column-5">AC power in 95-135 V<br
/> or 190-260 V</td></tr><tr
class="row-31 odd"><td
colspan="3" class="column-1 colspan-3">RS232 port</td><td
class="column-4">9-pin serial port</td><td
class="column-5"></td></tr></tbody></table><div
class="divider top"><a
href="#">Top</a></div><h2>515 BF02 Dimension Drawings</h2><div
class="one_third"></p><h3>Part Number</h3><p>515.XXXXXX-BF02</p><p>See product codes to select required features</p><p>Default application software:</p><p>515-BF02-000000</p><p></div><div
class="two_third last"></p><h3><img
class="alignnone size-full wp-image-581" title="515-dimensional-drawings" src="http://www.contrec.co.uk/wp-content/uploads/2011/04/515-dimensional-drawings.gif" alt="515 batch/flow computer dimensional drawings" width="624" height="349" /></h3><p></div><div
class="clearboth"></div><div
class="divider top"><a
href="#">Top</a></div><h2>515  Specifications</h2><div
class="one_half"></p><h3><p
class="fancy_header"><span>Operating Environment</span></p></h3><h5>Temperature</h5><p>-20 °C to +60 °C (conformal coating)<br
/> +5 °C to +40 °C (no coating)</p><h5>Humidity</h5><p>0 to 95% non condensing (conformal coating)<br
/> 5% to 85% non condensing (no coating)</p><h5>Power Supply</h5><p>95&#8230;135 V AC or 190&#8230;260 V AC or<br
/> 12&#8230;28 V DC</p><h5>Consumption</h5><p>6W (typical)</p><h5>Protection</h5><p>Sealed to IP65 (Nema 4X) when panel mounted</p><h5>Dimensions</h5><p>147 mm (5.8&#8243;) width<br
/> 74 mm (2.9&#8243;) height<br
/> 167 mm (6.6&#8243;) depth</p><h3><p
class="fancy_header"><span>Display</span></p></h3><h5>Type</h5><p>Backlit LCD with 7-digit numeric display and 11-character alphanumeric display</p><h5>Digits</h5><p>15.5 mm (0.6&#8243;) high</p><h5>Characters</h5><p>6 mm (0.24&#8243;) high</p><h5>LCD Backup</h5><p>Last data visible for 15 min after power down</p><h5>Update Rate</h5><p>0.3 second</p><h3><p
class="fancy_header"><span>Non-volatile Memory</span></p></h3><h5>Retention</h5><p>&gt; 30 years</p><h5>Data Stored</h5><p>Setup, Totals and Logs</p><h3><p
class="fancy_header"><span>Approvals</span></p></h3><h5>Interference</h5><p><strong>CE</strong> compliance</p><h5>Enclosure</h5><p><strong> </strong>ATEX, FM, CSA and SAA approved enclosures available for hazardous areas</p><h3><p
class="fancy_header"><span>Real Time Clock (Optional)</span></p></h3><h5>Battery Type</h5><p>3 volts Lithium button cell (CR2032)</p><h5>Battery Life</h5><p>5 years (typical)</p><h3><p
class="fancy_header"><span>Analog Input (General)</span></p></h3><h5>Overcurrent</h5><p><strong> </strong>100 mA absolute maximum rating</p><h5>Update Time</h5><p>&lt; 1.0 sec</p><h5>Configuration</h5><p><strong> </strong>4-20 mA, 0-5V and 1-5V input</p><h5>Non-linearity</h5><p><strong> </strong>Up to 20 correction points (flow inputs)</p><h3><p
class="fancy_header"><span>4-20 mA Input</span></p></h3><h5>Impedance</h5><p>100 ohms (to common signal ground)</p><h5>Accuracy</h5><p><strong> </strong>0.05% full scale (20 °C)</p><p>0.1% (full temperature range, typical)</p><p></div><div
class="one_half last"></p><h3><p
class="fancy_header"><span>0-5 or 1-5 Volts Input</span></p></h3><h5>Impedance</h5><p>10 Mohms (to common signal ground)</p><h5>Accuracy</h5><p>0.05% full scale (20 °C)</p><p>0.1% (full temperature range, typical)</p><h3><p
class="fancy_header"><span>Logic Inputs</span></p></h3><h5>Signal Type</h5><p><strong> </strong><strong> </strong>CMOS, TTL, open collector, reed switch</p><h5>Overvoltage</h5><p><strong> </strong>30V maximum</p><h3><p
class="fancy_header"><span>Relay Output</span></p></h3><h5>No. of Outputs</h5><p>2 relays plus 2 optional relays</p><h5>Voltage</h5><p>250 volts AC, 30 volts DC maximum (solid state relays use AC only)</p><h5>Current</h5><p>3 A maximum</p><h3><p
class="fancy_header"><span>Communication Ports</span></p></h3><h5>Ports</h5><p>RS-232 port<br
/> RS-485 port (optional)<br
/> Infra-red port</p><h5>Baud Rate</h5><p>2400 to 19200 baud</p><h5>Parity</h5><p>Odd, even or none</p><h5>Stop Bits</h5><p>1 or 2</p><h5>Protocols</h5><p>ASCII, Modbus RTU, Printer</p><h3><p
class="fancy_header"><span>Transducer Supply</span></p></h3><h5>Voltage</h5><p>8 to 24 volts DC, programmable</p><h5>Current</h5><p>70 mA @ 24 V, 120 mA @ 12 V maximum</p><h5>Protection</h5><p>Power limited output</p><h3><p
class="fancy_header"><span>Isolated Output</span></p></h3><h5>No. of Outputs</h5><p><strong> </strong>1 configurable output (plus 1 optional)</p><h5>Configuration</h5><p>Pulse/Digital or 4-20 mA output</p><h3><p
class="fancy_header"><span>Pulse/Digital Output</span></p></h3><h5>Signal Type</h5><p>Open collector</p><h5>Switching</h5><p><strong> </strong>200 mA, 30 volts DC maximum</p><h5>Saturation</h5><p>0.8 volts maximum</p><h5>Pulse Width</h5><p>Programmable: 10 , 20, 50, 100, 200 or 500ms</p><h3><p
class="fancy_header"><span>4-20mA Output (Optional)</span></p></h3><h5>Supply</h5><p>9 to 30 volts DC external</p><h5>Resolution</h5><p>0.05% full scale</p><h5>Accuracy</h5><p>0.05% full scale (20°C)<br
/> 0.1% (full temperature range, typical)</p><p><strong>Important:</strong> Specifications are subject to change without notice.</p><p></div><div
class="clearboth"></div><div
class="divider top"><a
href="#">Top</a></div><h2>Ordering Information</h2><h3>Product Codes</h3><table
id="wp-table-reloaded-id-46-no-1" class="wp-table-reloaded wp-table-reloaded-id-46"><thead><tr
class="row-1 odd"><th
class="column-1">Model</th><th
colspan="7" class="column-2 colspan-7">Supplementary Code</th><th
class="column-9">Description</th></tr></thead><tbody><tr
class="row-2 even"><td
class="column-1">515</td><td
class="column-2"></td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7">-</td><td
class="column-8">BF02</td><td
class="column-9"></td></tr><tr
class="row-3 odd"><td
class="column-1">Enclosure</td><td
class="column-2">1</td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Panel mount enclosure</td></tr><tr
class="row-4 even"><td
class="column-1">Enclosure</td><td
class="column-2">2</td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Field mount enclosure (not yet available)</td></tr><tr
class="row-5 odd"><td
class="column-1">Enclosure</td><td
class="column-2">3/5</td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Explosion proof Ex410 with metric glands (5 specifies heater version)</td></tr><tr
class="row-6 even"><td
class="column-1">Enclosure</td><td
class="column-2">4/6</td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Explosion proof Ex410 with NPT glands (6 specifies heater version)</td></tr><tr
class="row-7 odd"><td
colspan="2" class="column-1 colspan-2">Output Options</td><td
class="column-3">0</td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">4 logic inputs, 1 isolated output, 2 relays (only relay type 1 is available), RS232 (DB9) communication port</td></tr><tr
class="row-8 even"><td
colspan="2" class="column-1 colspan-2">Output Options</td><td
class="column-3">1</td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">4 logic inputs, 2 isolated outputs, 4 relays, real-time clock data logging, RS232 (DB9) and RS485 communication ports</td></tr><tr
class="row-9 odd"><td
colspan="2" class="column-1 colspan-2">Output Options</td><td
class="column-3">2/3</td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">4 logic inputs, 2 isolated outputs, 4 relays, real-time clock data logging, RS232 (DB9) and Ethernet/RF communication ports (not yet available)</td></tr><tr
class="row-10 even"><td
colspan="3" class="column-1 colspan-3">Relay Type</td><td
class="column-4">1</td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Electromechanical relays only</td></tr><tr
class="row-11 odd"><td
colspan="3" class="column-1 colspan-3">Relay Type</td><td
class="column-4">2</td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">2 electromechanical and 2 solid state relays</td></tr><tr
class="row-12 even"><td
colspan="3" class="column-1 colspan-3">Relay Type</td><td
class="column-4">3</td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Solid state relays only (not yet available)</td></tr><tr
class="row-13 odd"><td
class="column-1">Power Supply</td><td
class="column-2"></td><td
colspan="2" class="column-3 colspan-2"></td><td
class="column-5">E</td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">For 220/240 VAC</td></tr><tr
class="row-14 even"><td
class="column-1">Power Supply</td><td
class="column-2"></td><td
colspan="2" class="column-3 colspan-2"></td><td
class="column-5">A</td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">For 110/120 VAC</td></tr><tr
class="row-15 odd"><td
class="column-1">Power Supply</td><td
class="column-2"></td><td
colspan="2" class="column-3 colspan-2"></td><td
class="column-5">D</td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">For DC power only 12-28 VDC</td></tr><tr
class="row-16 even"><td
class="column-1">Display Panel Options</td><td
class="column-2"></td><td
class="column-3"></td><td
colspan="2" class="column-4 colspan-2"></td><td
class="column-6">F</td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Fully optioned (with backlight, LCD backup and Infra-Red comms port)</td></tr><tr
class="row-17 odd"><td
class="column-1">PCB Protection</td><td
class="column-2"></td><td
class="column-3"></td><td
class="column-4"></td><td
colspan="2" class="column-5 colspan-2"></td><td
class="column-7">C</td><td
class="column-8"></td><td
class="column-9">Conformal coating - required for maximum environmental operating range. Recommended to avoid damage from moisture and corrosion.</td></tr><tr
class="row-18 even"><td
class="column-1">PCB Protection</td><td
class="column-2"></td><td
class="column-3"></td><td
class="column-4"></td><td
colspan="2" class="column-5 colspan-2"></td><td
class="column-7">N</td><td
class="column-8"></td><td
class="column-9">None - suitable for IEC standard 654-1 Climatic Conditions up to Class B2 (Heated and/or cooled enclosed locations)</td></tr><tr
class="row-19 odd"><td
class="column-1">Application Pack Number</td><td
class="column-2"></td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8">BF02</td><td
class="column-9">Defines the application software to be loaded into the instrument</td></tr></tbody></table><div
class="divider top"><a
href="#">Top</a></div><div
class="one_half"></p><h3>Main Menu Variables</h3><p><table
id="wp-table-reloaded-id-40-no-1" class="wp-table-reloaded wp-table-reloaded-id-40"><thead><tr
class="row-1 odd"><th
class="column-1">Main Menu Variables</th><th
class="column-2">Default Units</th><th
class="column-3">Preferred Units</th><th
class="column-4">Variable Type</th></tr></thead><tbody><tr
class="row-2 even"><td
class="column-1">Volume</td><td
class="column-2">Ltr</td><td
class="column-3"></td><td
class="column-4">Total</td></tr><tr
class="row-3 odd"><td
class="column-1">Volume Flowrate</td><td
class="column-2">L/min</td><td
class="column-3"></td><td
class="column-4">Rate</td></tr><tr
class="row-4 even"><td
class="column-1">Control Output</td><td
class="column-2">%</td><td
class="column-3"></td><td
class="column-4">Rate</td></tr><tr
class="row-5 odd"><td
class="column-1">Flowrate Deviation</td><td
class="column-2">%</td><td
class="column-3"></td><td
class="column-4">Rate</td></tr></tbody></table></p><p>Please specify the preferred units of measurement.</p><p></div><div
class="one_half last"></p><p><div
id="attachment_446" class="wp-caption alignnone" style="width: 466px"><img
class="size-full wp-image-446 " title="500-batch-enclosure" src="http://www.contrec.co.uk/wp-content/uploads/2011/04/500-batch-enclosure.jpg" alt="500 Series in Ex410 Enclosure" width="456" height="441" /><p
class="wp-caption-text">500 Series in Ex410 Enclosure</p></div></p><p></div><div
class="clearboth"></div><div
class="divider top"><a
href="#">Top</a></div><h2>Product Manual Download</h2><div
class="download_box"><a
title="Product Manual Download" href="http://www.contrec.co.uk/wp-content/uploads/2011/09/515-BF02-OM.pdf" target="_blank">Click here to download the 515BF02 product manual</a></div> ]]></content:encoded> <wfw:commentRss>http://www.contrec.co.uk/515-bf02/feed/</wfw:commentRss> <slash:comments>0</slash:comments> </item> <item><title>515 &#8211; BF03</title><link>http://www.contrec.co.uk/515-bf03/</link> <comments>http://www.contrec.co.uk/515-bf03/#comments</comments> <pubDate>Fri, 15 Apr 2011 06:44:44 +0000</pubDate> <dc:creator>Nick</dc:creator> <category><![CDATA[515 Series]]></category> <category><![CDATA[Batch Controllers]]></category> <category><![CDATA[515 BF03]]></category> <category><![CDATA[backlit display]]></category> <category><![CDATA[backup check]]></category> <category><![CDATA[batch control]]></category> <category><![CDATA[correct delivery]]></category> <category><![CDATA[dual stage]]></category> <category><![CDATA[flow controller]]></category> <category><![CDATA[frequency input]]></category> <category><![CDATA[loop control]]></category> <category><![CDATA[loop mode]]></category> <category><![CDATA[overflow error]]></category> <category><![CDATA[pi control]]></category> <category><![CDATA[preset value]]></category> <category><![CDATA[printer output]]></category> <category><![CDATA[proportional valve]]></category> <category><![CDATA[rtu]]></category> <category><![CDATA[serial ports]]></category> <category><![CDATA[stage control]]></category> <category><![CDATA[valve closure]]></category> <category><![CDATA[valves and actuators]]></category> <category><![CDATA[volume flow]]></category><guid
isPermaLink="false">http://www.contrec.co.uk/?p=622</guid> <description><![CDATA[Overview Terminal Designations 515 BF03 Dimension Drawings 515  Specifications Ordering Information Product Codes Product Manual Download]]></description> <content:encoded><![CDATA[<h2>Overview</h2><div
class="one_third"></p><p>The 515 BF03 application is a batching flow controller for delivery of preset quantities at preset flowrates using a mass frequency input. Batch control can operate in preset or on-off modes, while flow control can be set to local (manual) or PI loop mode.</p><p>This application provides the operator with clear local readout including flowrate deviation and can be controlled via communications in more automated systems. There is quick access to commonly used preset values directly from the front panel if access has been authorized.</p><p>The PI control of the process flow is via a 4-20mA proportional valve or pump controller. It has integral wind- up protection, a deadband, output hold and ramp time that can be programmed to reduce wear on valves and actuators and provide for bumpless operation.</p><p></div><div
class="one_third"></p><h4>Calculations</h4><p>The total and flowrate are derived from accurately measured frequency and the number of received pulses.</p><p><em>volume = pulses / k-factor</em></p><p><em>volume flow = frequency / k-factor</em></p><p>Automatic overrun compensation calculates the new valve closure point to ensure correct delivery by averageing the overrun amount from the last three complete batches.</p><p>The overrun compensation value is valid for a new preset value provided the stored overrun is less than 20% of the new preset.</p><p></div><div
class="one_third last"></p><h3>Features at a glance</h3><p></p><ul
class="check_list"><li>Tailored for volumetric frequency flow input</li><li>Single or Dual stage control</li><li>Preset or manual On-Off modes</li><li>Easy access to batch and flow rate presets</li><li>No-flow, leakage and overflow error detection</li><li>Remote RUN/STOP/RESET</li><li>Allows for permissive with prompt</li><li>Uses PI Loop Control</li><li>Allows for non-linear correction</li><li>Storage of 1000 transactions with time and date stamp</li><li>Selection of second language and user tags</li><li>Selectable protocols on serial ports including Modbus RTU and Printer output</li><li>Backlit display with LCD backup</li></ul><p></p><p></div><div
class="clearboth"></div><p><img
class="alignnone size-full wp-image-641" title="BF03-diagram" src="http://www.contrec.co.uk/wp-content/uploads/2011/04/BF03-diagram.jpg" alt="BF03 batch/flow computer diagram" width="910" height="264" /></p><div
class="divider top"><a
href="#">Top</a></div><div
class="one_half"></p><h4>Displayed Information</h4><p>The front panel display shows the current values of the input variables and the results of the calculations. A list of the variables for this application and their type (total or rate) is shown at the end of this document.</p><p>The instrument can be supplied with a real-time clock for storage of up to 100 transactions with time and date stamps.</p><h4>Communications</h4><p>There are three communication ports available as follows:</p><p></p><ul
class="arrow_list"><li>RS-232 port (standard)</li><li>RS-485 port (advanced option)</li><li>Infra-red port (on front panel)</li></ul><p></p><p>The ports are available for remote data reading, printouts and for initial application loading of the instrument.</p><h4>Isolated Outputs</h4><p>The opto-isolated outputs can retransmit any main menu variable. The type of output is determined by the nature of the assigned variable. Totals are output as pulses and rates are output as 4-20 mA signals. One output is standard, a second output is available as an option.</p><p></div><div
class="one_half last"></p><h4>Relay Outputs</h4><p>The relay outputs 1 and 2 are used to control the flow of product for each delivery. These contacts are normally open and can be used to drive external relays, valves, pump circuits etc.</p><h4>Software Configuration</h4><p>The instrument can be further tailored to suit specific application needs including units of measurement, custom tags, second language or access levels. A distributor can configure these requirements before delivery.</p><p>Instrument parameters including units of measurement can be programmed in the field, according to the user access levels assigned to parameters by the distributor.</p><p>All set-up parameters, totals and logged data are stored in non-volatile memory with at least 30 years retention.</p><p>&nbsp;</p><p><img
class="alignnone size-full wp-image-549" title="500-batch-computer-side" src="http://www.contrec.co.uk/wp-content/uploads/2011/04/500-batch-computer-side.jpg" alt="500 series batch computer" width="456" height="257" /></p><p></div><div
class="clearboth"></div><div
class="divider top"><a
href="#">Top</a></div><h2>Terminal Designations</h2><table
id="wp-table-reloaded-id-173-no-1" class="wp-table-reloaded wp-table-reloaded-id-173"><thead><tr
class="row-1"><th
class="column-1">Terminal Label</th><th
class="column-2"></th><th
class="column-3"></th><th
class="column-4">Designation</th><th
class="column-5">Comment</th></tr></thead><tbody
class="row-hover"><tr
class="row-2"><td
class="column-1">1</td><td
class="column-2">FINP</td><td
class="column-3">1+</td><td
class="column-4">Frequency Input 1+</td><td
class="column-5">Mass flow Input</td></tr><tr
class="row-3"><td
class="column-1">3</td><td
class="column-2">SG</td><td
class="column-3">-</td><td
class="column-4">Signal Ground</td><td
class="column-5"></td></tr><tr
class="row-4"><td
class="column-1">15</td><td
class="column-2">Vo</td><td
class="column-3">+</td><td
class="column-4">8-24 volts DC output</td><td
class="column-5">Overload protected</td></tr><tr
class="row-5"><td
class="column-1">16</td><td
class="column-2">G</td><td
class="column-3">-</td><td
class="column-4">DC Ground</td><td
class="column-5"></td></tr><tr
class="row-6"><td
class="column-1">17</td><td
class="column-2">Vi</td><td
class="column-3">+</td><td
class="column-4">DC power input</td><td
class="column-5">DC power in 12-28V</td></tr><tr
class="row-7"><td
class="column-1">18</td><td
class="column-2">SH</td><td
class="column-3">E</td><td
class="column-4">Shield terminal</td><td
class="column-5"></td></tr><tr
class="row-8"><td
class="column-1">19</td><td
class="column-2">RS485</td><td
class="column-3">+</td><td
class="column-4">RS485 (+)</td><td
class="column-5">Advanced option</td></tr><tr
class="row-9"><td
class="column-1">20</td><td
class="column-2">RS485</td><td
class="column-3">-</td><td
class="column-4">RS485 (-)</td><td
class="column-5">Advanced option</td></tr><tr
class="row-10"><td
class="column-1">21</td><td
class="column-2">RS485</td><td
class="column-3">G</td><td
class="column-4">RS485 Ground</td><td
class="column-5">Advanced option</td></tr><tr
class="row-11"><td
class="column-1">22</td><td
class="column-2">LOGIC INPUTS</td><td
class="column-3">1+</td><td
class="column-4">Switch 1</td><td
class="column-5">Remote Run</td></tr><tr
class="row-12"><td
class="column-1">23</td><td
class="column-2">LOGIC INPUTS</td><td
class="column-3">2+</td><td
class="column-4">Switch 2</td><td
class="column-5">Remote Stop</td></tr><tr
class="row-13"><td
class="column-1">24</td><td
class="column-2">LOGIC INPUTS</td><td
class="column-3">3+</td><td
class="column-4">Switch 3</td><td
class="column-5">Remote Reset</td></tr><tr
class="row-14"><td
class="column-1">25</td><td
class="column-2">LOGIC INPUTS</td><td
class="column-3">4+</td><td
class="column-4">Switch 4</td><td
class="column-5">Permissive Input</td></tr><tr
class="row-15"><td
class="column-1">26</td><td
class="column-2">LOGIC INPUTS</td><td
class="column-3">C-</td><td
class="column-4">Signal ground</td><td
class="column-5"></td></tr><tr
class="row-16"><td
class="column-1">27</td><td
class="column-2">OUT 1</td><td
class="column-3">+</td><td
class="column-4">Output ch 1 (+)</td><td
class="column-5">Process control output</td></tr><tr
class="row-17"><td
class="column-1">28</td><td
class="column-2">OUT 1</td><td
class="column-3">-</td><td
class="column-4">Output ch 1 (-)</td><td
class="column-5">Process control output</td></tr><tr
class="row-18"><td
class="column-1">29</td><td
class="column-2">OUT 2</td><td
class="column-3">+</td><td
class="column-4">Output ch 2 (+)</td><td
class="column-5">Optional Output</td></tr><tr
class="row-19"><td
class="column-1">30</td><td
class="column-2">OUT 2</td><td
class="column-3">-</td><td
class="column-4">Output ch 2 (-)</td><td
class="column-5">Optional Ouput</td></tr><tr
class="row-20"><td
class="column-1">31</td><td
class="column-2">RELAYS</td><td
class="column-3">RC</td><td
class="column-4">Relay common</td><td
class="column-5"></td></tr><tr
class="row-21"><td
class="column-1">32</td><td
class="column-2">RELAYS</td><td
class="column-3">R1</td><td
class="column-4">Relay 1</td><td
class="column-5">Single stage control</td></tr><tr
class="row-22"><td
class="column-1">33</td><td
class="column-2">RELAYS</td><td
class="column-3">R2</td><td
class="column-4">Relay 2</td><td
class="column-5">Dual stage control</td></tr><tr
class="row-23"><td
class="column-1">34</td><td
class="column-2">RELAYS</td><td
class="column-3">R3</td><td
class="column-4">Relay 3</td><td
class="column-5">Advanced option</td></tr><tr
class="row-24"><td
class="column-1">35</td><td
class="column-2">RELAYS</td><td
class="column-3">R4</td><td
class="column-4">Relay 4</td><td
class="column-5">Advanced option</td></tr><tr
class="row-25"><td
class="column-1">E</td><td
class="column-2">AC MAINS</td><td
class="column-3">E</td><td
class="column-4">Mains ground</td><td
class="column-5">AC power in 95-135V or 190-260V</td></tr><tr
class="row-26"><td
class="column-1">N</td><td
class="column-2">AC MAINS</td><td
class="column-3">N</td><td
class="column-4">Mains neutral</td><td
class="column-5">AC power in 95-135V or 190-260V</td></tr><tr
class="row-27"><td
class="column-1">A</td><td
class="column-2">AC MAINS</td><td
class="column-3">A</td><td
class="column-4">Mains active</td><td
class="column-5">AC power in 95-135V or 190-260V</td></tr><tr
class="row-28"><td
class="column-1">RS232 port</td><td
class="column-2"></td><td
class="column-3">9-pin serial port</td><td
class="column-4"></td><td
class="column-5"></td></tr></tbody></table><div
class="divider top"><a
href="#">Top</a></div><h2>515 BF03 Dimension Drawings</h2><div
class="one_third"></p><h3>Part Number</h3><p>515.XXXXXX-BF03</p><p>See product codes to select required features</p><p>Default application software:</p><p>515-BF03-000000</p><p></div><div
class="two_third last"></p><h3><img
class="alignnone size-full wp-image-581" title="515-dimensional-drawings" src="http://www.contrec.co.uk/wp-content/uploads/2011/04/515-dimensional-drawings.gif" alt="515 batch/flow computer dimensional drawings" width="624" height="349" /></h3><p></div><div
class="clearboth"></div><div
class="divider top"><a
href="#">Top</a></div><h2>515  Specifications</h2><div
class="one_half"></p><h3><p
class="fancy_header"><span>Operating Environment</span></p></h3><h5>Temperature</h5><p>-20 °C to +60 °C (conformal coating)<br
/> +5 °C to +40 °C (no coating)</p><h5>Humidity</h5><p>0 to 95% non condensing (conformal coating)<br
/> 5% to 85% non condensing (no coating)</p><h5>Power Supply</h5><p>95&#8230;135 V AC or 190&#8230;260 V AC or<br
/> 12&#8230;28 V DC</p><h5>Consumption</h5><p>6W (typical)</p><h5>Protection</h5><p>Sealed to IP65 (Nema 4X) when panel mounted</p><h5>Dimensions</h5><p>147 mm (5.8&#8243;) width<br
/> 74 mm (2.9&#8243;) height<br
/> 167 mm (6.6&#8243;) depth</p><h3><p
class="fancy_header"><span>Display</span></p></h3><h5>Type</h5><p>Backlit LCD with 7-digit numeric display and 11-character alphanumeric display</p><h5>Digits</h5><p>15.5 mm (0.6&#8243;) high</p><h5>Characters</h5><p>6 mm (0.24&#8243;) high</p><h5>LCD Backup</h5><p>Last data visible for 15 min after power down</p><h5>Update Rate</h5><p>0.3 second</p><h3><p
class="fancy_header"><span>Non-volatile Memory</span></p></h3><h5>Retention</h5><p>&gt; 30 years</p><h5>Data Stored</h5><p>Setup, Totals and Logs</p><h3><p
class="fancy_header"><span>Approvals</span></p></h3><h5>Interference</h5><p><strong>CE</strong> compliance</p><h5>Enclosure</h5><p><strong> </strong>ATEX, FM, CSA and SAA approved enclosures available for hazardous areas</p><h3><p
class="fancy_header"><span>Real Time Clock (Optional)</span></p></h3><h5>Battery Type</h5><p>3 volts Lithium button cell (CR2032)</p><h5>Battery Life</h5><p>5 years (typical)</p><h3><p
class="fancy_header"><span>Frequency Input (General)</span></p></h3><h5>Range</h5><p>0 to 10 kHz</p><h5>Over Voltage</h5><p>30 V maximum</p><h5>Update Time</h5><p>0.3 sec</p><h5>Cutoff Frequency</h5><p>Programmable</p><h5>Configuration</h5><p>Pulse, coil or NPS input</p><h5>Non-linearity</h5><p>Up to 10 correction points</p><h3><p
class="fancy_header"><span>Pulse</span></p></h3><h5>Signal Type</h5><p>CMOS, TTL, open collector, reed switch</p><h5>Threshold</h5><p>1.3 volts</p><p></div><div
class="one_half last"></p><h3><p
class="fancy_header"><span>Coil</span></p></h3><h5>Signal Type</h5><p>Turbine and sine wave</p><h5>Sensitivity</h5><p><strong> </strong>15 mV p-p minimum</p><h3><p
class="fancy_header"><span>NPS</span></p></h3><h5>Signal Type</h5><p>NPS sensor to Namur standard</p><h3><p
class="fancy_header"><span>Logic Inputs</span></p></h3><h5>Signal Type</h5><p><strong> </strong><strong> </strong>CMOS, TTL, open collector, reed switch</p><h5>Overvoltage</h5><p><strong> </strong>30V maximum</p><h3><p
class="fancy_header"><span>Relay Output</span></p></h3><h5>No. of Outputs</h5><p>2 relays plus 2 optional relays</p><h5>Voltage</h5><p>250 volts AC, 30 volts DC maximum (solid state relays use AC only)</p><h5>Current</h5><p>3 A maximum</p><h3><p
class="fancy_header"><span>Communication Ports</span></p></h3><h5>Ports</h5><p>RS-232 port<br
/> RS-485 port (optional)<br
/> Infra-red port</p><h5>Baud Rate</h5><p>2400 to 19200 baud</p><h5>Parity</h5><p>Odd, even or none</p><h5>Stop Bits</h5><p>1 or 2</p><h5>Protocols</h5><p>ASCII, Modbus RTU, Printer</p><h3><p
class="fancy_header"><span>Transducer Supply</span></p></h3><h5>Voltage</h5><p>8 to 24 volts DC, programmable</p><h5>Current</h5><p>70 mA @ 24 V, 120 mA @ 12 V maximum</p><h5>Protection</h5><p>Power limited output</p><h3><p
class="fancy_header"><span>Isolated Output</span></p></h3><h5>No. of Outputs</h5><p><strong> </strong>1 configurable output (plus 1 optional)</p><h5>Configuration</h5><p>Pulse/Digital or 4-20 mA output</p><h3><p
class="fancy_header"><span>Pulse/Digital Output</span></p></h3><h5>Signal Type</h5><p>Open collector</p><h5>Switching</h5><p><strong> </strong>200 mA, 30 volts DC maximum</p><h5>Saturation</h5><p>0.8 volts maximum</p><h5>Pulse Width</h5><p>Programmable: 10 , 20, 50, 100, 200 or 500ms</p><h3><p
class="fancy_header"><span>4-20mA Output (Optional)</span></p></h3><h5>Supply</h5><p>9 to 30 volts DC external</p><h5>Resolution</h5><p>0.05% full scale</p><h5>Accuracy</h5><p>0.05% full scale (20°C)<br
/> 0.1% (full temperature range, typical)</p><p><strong>Important:</strong> Specifications are subject to change without notice.</p><p></div><div
class="clearboth"></div><div
class="divider top"><a
href="#">Top</a></div><h2>Ordering Information</h2><h3>Product Codes</h3><table
id="wp-table-reloaded-id-45-no-1" class="wp-table-reloaded wp-table-reloaded-id-45"><thead><tr
class="row-1 odd"><th
class="column-1">Model</th><th
colspan="7" class="column-2 colspan-7">Supplementary Code</th><th
class="column-9">Description</th></tr></thead><tbody><tr
class="row-2 even"><td
class="column-1">515</td><td
class="column-2"></td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7">-</td><td
class="column-8">BF03</td><td
class="column-9"></td></tr><tr
class="row-3 odd"><td
class="column-1">Enclosure</td><td
class="column-2">1</td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Panel mount enclosure</td></tr><tr
class="row-4 even"><td
class="column-1">Enclosure</td><td
class="column-2">2</td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Field mount enclosure (not yet available)</td></tr><tr
class="row-5 odd"><td
class="column-1">Enclosure</td><td
class="column-2">3/5</td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Explosion proof Ex410 with metric glands (5 specifies heater version)</td></tr><tr
class="row-6 even"><td
class="column-1">Enclosure</td><td
class="column-2">4/6</td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Explosion proof Ex410 with NPT glands (6 specifies heater version)</td></tr><tr
class="row-7 odd"><td
colspan="2" class="column-1 colspan-2">Output Options</td><td
class="column-3">0</td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">4 logic inputs, 1 isolated output, 2 relays (only relay type 1 is available), RS232 (DB9) communication port</td></tr><tr
class="row-8 even"><td
colspan="2" class="column-1 colspan-2">Output Options</td><td
class="column-3">1</td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">4 logic inputs, 2 isolated outputs, 4 relays, real-time clock data logging, RS232 (DB9) and RS485 communication ports</td></tr><tr
class="row-9 odd"><td
colspan="2" class="column-1 colspan-2">Output Options</td><td
class="column-3">2/3</td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">4 logic inputs, 2 isolated outputs, 4 relays, real-time clock data logging, RS232 (DB9) and Ethernet/RF communication ports (not yet available)</td></tr><tr
class="row-10 even"><td
colspan="3" class="column-1 colspan-3">Relay Type</td><td
class="column-4">1</td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Electromechanical relays only</td></tr><tr
class="row-11 odd"><td
colspan="3" class="column-1 colspan-3">Relay Type</td><td
class="column-4">2</td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">2 electromechanical and 2 solid state relays</td></tr><tr
class="row-12 even"><td
colspan="3" class="column-1 colspan-3">Relay Type</td><td
class="column-4">3</td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Solid state relays only (not yet available)</td></tr><tr
class="row-13 odd"><td
class="column-1">Power Supply</td><td
class="column-2"></td><td
colspan="2" class="column-3 colspan-2"></td><td
class="column-5">E</td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">For 220/240 VAC</td></tr><tr
class="row-14 even"><td
class="column-1">Power Supply</td><td
class="column-2"></td><td
colspan="2" class="column-3 colspan-2"></td><td
class="column-5">A</td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">For 110/120 VAC</td></tr><tr
class="row-15 odd"><td
class="column-1">Power Supply</td><td
class="column-2"></td><td
colspan="2" class="column-3 colspan-2"></td><td
class="column-5">D</td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">For DC power only 12-28 VDC</td></tr><tr
class="row-16 even"><td
class="column-1">Display Panel Options</td><td
class="column-2"></td><td
class="column-3"></td><td
colspan="2" class="column-4 colspan-2"></td><td
class="column-6">F</td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Fully optioned (with backlight, LCD backup and Infra-Red comms port)</td></tr><tr
class="row-17 odd"><td
class="column-1">PCB Protection</td><td
class="column-2"></td><td
class="column-3"></td><td
class="column-4"></td><td
colspan="2" class="column-5 colspan-2"></td><td
class="column-7">C</td><td
class="column-8"></td><td
class="column-9">Conformal coating - required for maximum environmental operating range. Recommended to avoid damage from moisture and corrosion.</td></tr><tr
class="row-18 even"><td
class="column-1">PCB Protection</td><td
class="column-2"></td><td
class="column-3"></td><td
class="column-4"></td><td
colspan="2" class="column-5 colspan-2"></td><td
class="column-7">N</td><td
class="column-8"></td><td
class="column-9">None - suitable for IEC standard 654-1 Climatic Conditions up to Class B2 (Heated and/or cooled enclosed locations)</td></tr><tr
class="row-19 odd"><td
class="column-1">Application Pack Number</td><td
class="column-2"></td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8">BF03</td><td
class="column-9">Defines the application software to be loaded into the instrument</td></tr></tbody></table><div
class="divider top"><a
href="#">Top</a></div><div
class="one_half"></p><h3>Main Menu Variables</h3><p><table
id="wp-table-reloaded-id-44-no-1" class="wp-table-reloaded wp-table-reloaded-id-44"><thead><tr
class="row-1 odd"><th
class="column-1">Main Menu Variables</th><th
class="column-2">Default Units</th><th
class="column-3">Preferred Units</th><th
class="column-4">Variable Type</th></tr></thead><tbody><tr
class="row-2 even"><td
class="column-1">Mass</td><td
class="column-2">kg</td><td
class="column-3"></td><td
class="column-4">Total</td></tr><tr
class="row-3 odd"><td
class="column-1">Mass Flowrate</td><td
class="column-2">kg/min</td><td
class="column-3"></td><td
class="column-4">Rate</td></tr><tr
class="row-4 even"><td
class="column-1">Control Output</td><td
class="column-2">%</td><td
class="column-3"></td><td
class="column-4">Rate</td></tr><tr
class="row-5 odd"><td
class="column-1">Flowrate Deviation</td><td
class="column-2">%</td><td
class="column-3"></td><td
class="column-4">Rate</td></tr></tbody></table></p><p>Please specify the preferred units of measurement.</p><p></div><div
class="one_half last"></p><p><div
id="attachment_446" class="wp-caption alignnone" style="width: 466px"><img
class="size-full wp-image-446 " title="500-batch-enclosure" src="http://www.contrec.co.uk/wp-content/uploads/2011/04/500-batch-enclosure.jpg" alt="500 Series in Ex410 Enclosure" width="456" height="441" /><p
class="wp-caption-text">500 Series in Ex410 Enclosure</p></div></p><p></div><div
class="clearboth"></div><div
class="divider top"><a
href="#">Top</a></div><h2>Product Manual Download</h2><div
class="download_box"><a
title="Product Manual Download" href="http://www.contrec.co.uk/wp-content/uploads/2011/09/515-BF03-OM.pdf" target="_blank">Click here to download the 515 BF03 product manual</a></div> ]]></content:encoded> <wfw:commentRss>http://www.contrec.co.uk/515-bf03/feed/</wfw:commentRss> <slash:comments>0</slash:comments> </item> <item><title>515 &#8211; BF04</title><link>http://www.contrec.co.uk/515-bf04-2/</link> <comments>http://www.contrec.co.uk/515-bf04-2/#comments</comments> <pubDate>Fri, 15 Apr 2011 06:09:39 +0000</pubDate> <dc:creator>Nick</dc:creator> <category><![CDATA[515 Series]]></category> <category><![CDATA[Batch Controllers]]></category> <category><![CDATA[515 BF04]]></category> <category><![CDATA[analog input]]></category> <category><![CDATA[backlit display]]></category> <category><![CDATA[backup check]]></category> <category><![CDATA[batch control]]></category> <category><![CDATA[bf04]]></category> <category><![CDATA[correct delivery]]></category> <category><![CDATA[dual stage]]></category> <category><![CDATA[flow controller]]></category> <category><![CDATA[loop control]]></category> <category><![CDATA[loop mode]]></category> <category><![CDATA[mass flow]]></category> <category><![CDATA[overflow error]]></category> <category><![CDATA[pi control]]></category> <category><![CDATA[preset value]]></category> <category><![CDATA[printer output]]></category> <category><![CDATA[proportional valve]]></category> <category><![CDATA[serial ports]]></category> <category><![CDATA[stage control]]></category> <category><![CDATA[valve closure]]></category> <category><![CDATA[valves and actuators]]></category><guid
isPermaLink="false">http://www.contrec.co.uk/?p=590</guid> <description><![CDATA[Overview Terminal Designations 515 BF04 Dimension Drawings 515  Specifications Ordering Information Product Codes &#160; Product Manual Download]]></description> <content:encoded><![CDATA[<h2>Overview</h2><div
class="one_third"></p><p>The 515 BF04 application is a batching flow controller for delivery of preset quantities at preset flowrates using a mass analog input. Batch control can operate in preset or on-off modes, while flow control can be set to local (manual) or PI loop mode.</p><p>This application provides the operator with clear local readout including flowrate deviation and can be controlled via communications in more automated systems. There is quick access to commonly used preset values directly from the front panel if access has been authorized.</p><p>The PI control of the process flow is via a 4-20mA proportional valve or pump controller. It has integral wind- up protection, a deadband, output hold and ramp time that can be programmed to reduce wear on valves and actuators and provide for bumpless operation.</p><p></div><div
class="one_third"></p><h4>Calculations</h4><p>To derive the flow rate, the analog input is normalised to a value (A) between 0 and 1.</p><p><em>mass flow = (M</em><em><sub>f</sub> </em><em>max &#8211; M</em><em><sub>f</sub> </em><em>m</em><em>i</em><em>n</em><em>)A + M</em><em><sub>f</sub> </em><em>min mass </em>= ∫( <em>ma</em><em>ssflo</em><em>w </em>× Δ<em>t </em>)</p><p>Automatic overrun compensation calculates the new valve closure point to ensure correct delivery by averageing the overrun amount from the last three complete batches.</p><p>The overrun compensation value is valid for a new preset value provided the stored overrun is less than 20% of the new preset.</p><p></div><div
class="one_third last"></p><h3>Features at a glance</h3><p></p><ul
class="check_list"><li>Tailored for mass analog flow input</li><li>Single or Dual stage control</li><li>Preset or manual On-Off modes</li><li>Easy access to batch and flow rate presets</li><li>No-flow, leakage and overflow error detection</li><li>Remote RUN/STOP/RESET</li><li>Allows for permissive with prompt</li><li>Uses PI Loop Control</li><li>Allows for non-linear correction</li><li>Storage of 1000 transactions with time and date stamp</li><li>Selection of second language and user tags</li><li>Selectable protocols on serial ports including Modbus RTU and Printer output</li><li>Backlit display with LCD backup</li></ul><p></p><p></div><div
class="clearboth"></div><p><img
class="alignnone size-full wp-image-642" title="BF04-diagram" src="http://www.contrec.co.uk/wp-content/uploads/2011/04/BF04-diagram.jpg" alt="BF04 batch/flow computer diagram" width="910" height="264" /></p><div
class="divider top"><a
href="#">Top</a></div><div
class="one_half"></p><h4>Displayed Information</h4><p>The front panel display shows the current values of the input variables and the results of the calculations. A list of the variables for this application and their type (total or rate) is shown at the end of this document.</p><p>The instrument can be supplied with a real-time clock for storage of up to 100 transactions with time and date stamps.</p><h4>Communications</h4><p>There are three communication ports available as follows:</p><p></p><ul
class="arrow_list"><li>RS-232 port (standard)</li><li>RS-485 port (advanced option)</li><li>Infra-red port (on front panel)</li></ul><p></p><p>The ports are available for remote data reading, printouts and for initial application loading of the instrument.</p><h4>Isolated Outputs</h4><p>The opto-isolated outputs can retransmit any main menu variable. The type of output is determined by the nature of the assigned variable. Totals are output as pulses and rates are output as 4-20 mA signals. One output is standard, a second output is available as an option.</p><p></div><div
class="one_half last"></p><h4>Relay Outputs</h4><p>The relay outputs 1 and 2 are used to control the flow of product for each delivery. These contacts are normally open and can be used to drive external relays, valves, pump circuits etc.</p><h4>Software Configuration</h4><p>The instrument can be further tailored to suit specific application needs including units of measurement, custom tags, second language or access levels. A distributor can configure these requirements before delivery.</p><p>Instrument parameters including units of measurement can be programmed in the field, according to the user access levels assigned to parameters by the distributor.</p><p>All set-up parameters, totals and logged data are stored in non-volatile memory with at least 30 years retention.</p><p>&nbsp;</p><p><img
class="alignnone size-full wp-image-549" title="500-batch-computer-side" src="http://www.contrec.co.uk/wp-content/uploads/2011/04/500-batch-computer-side.jpg" alt="500 series batch computer" width="456" height="257" /></p><p></div><div
class="clearboth"></div><div
class="divider top"><a
href="#">Top</a></div><h2>Terminal Designations</h2><table
id="wp-table-reloaded-id-41-no-1" class="wp-table-reloaded wp-table-reloaded-id-41"><thead><tr
class="row-1 odd"><th
colspan="3" class="column-1 colspan-3">Terminal Label</th><th
class="column-4">Designation</th><th
class="column-5">Comment</th></tr></thead><tbody><tr
class="row-2 even"><td
class="column-1">3</td><td
class="column-2">SG</td><td
class="column-3">-</td><td
class="column-4">Signal ground</td><td
class="column-5"></td></tr><tr
class="row-3 odd"><td
class="column-1">11</td><td
class="column-2">AINP3</td><td
class="column-3">+</td><td
class="column-4">Analog input ch 3 (+)</td><td
class="column-5">Main or low flow input</td></tr><tr
class="row-4 even"><td
class="column-1">12</td><td
class="column-2">AINP3</td><td
class="column-3">-</td><td
class="column-4">Analog input ch 3 (-)</td><td
class="column-5">Main or low flow input</td></tr><tr
class="row-5 odd"><td
class="column-1">13</td><td
class="column-2">AINP4</td><td
class="column-3">+</td><td
class="column-4">Analog input ch 4 (+)</td><td
class="column-5">High flow stacked input</td></tr><tr
class="row-6 even"><td
class="column-1">14</td><td
class="column-2">AINP4</td><td
class="column-3">-</td><td
class="column-4">Analog input ch 4 (-)</td><td
class="column-5">High flow stacked input</td></tr><tr
class="row-7 odd"><td
class="column-1">15</td><td
class="column-2">Vo</td><td
class="column-3">+</td><td
class="column-4">8-24 volts DC output</td><td
class="column-5">Overload protected</td></tr><tr
class="row-8 even"><td
class="column-1">16</td><td
class="column-2">G</td><td
class="column-3">-</td><td
class="column-4">DC Ground</td><td
class="column-5"></td></tr><tr
class="row-9 odd"><td
class="column-1">17</td><td
class="column-2">Vi</td><td
class="column-3">+</td><td
class="column-4">DC power input</td><td
class="column-5">DC power in 12-28V</td></tr><tr
class="row-10 even"><td
class="column-1">18</td><td
class="column-2">SH</td><td
class="column-3">E</td><td
class="column-4">Shield Terminal</td><td
class="column-5"></td></tr><tr
class="row-11 odd"><td
class="column-1">19</td><td
class="column-2">RS485</td><td
class="column-3">+</td><td
class="column-4">RS485(+)</td><td
class="column-5">Advanced option</td></tr><tr
class="row-12 even"><td
class="column-1">20</td><td
class="column-2">RS485</td><td
class="column-3">-</td><td
class="column-4">RS485(+)</td><td
class="column-5">Advanced option</td></tr><tr
class="row-13 odd"><td
class="column-1">21</td><td
class="column-2">RS485</td><td
class="column-3">G</td><td
class="column-4">RS485 ground</td><td
class="column-5">Advanced option</td></tr><tr
class="row-14 even"><td
class="column-1">22</td><td
class="column-2">Logic Inputs</td><td
class="column-3">1+</td><td
class="column-4">Switch 1</td><td
class="column-5">Remote Run</td></tr><tr
class="row-15 odd"><td
class="column-1">23</td><td
class="column-2">Logic Inputs</td><td
class="column-3">2+</td><td
class="column-4">Switch 2</td><td
class="column-5">Remote Stop</td></tr><tr
class="row-16 even"><td
class="column-1">24</td><td
class="column-2">Logic Inputs</td><td
class="column-3">3+</td><td
class="column-4">Switch 3</td><td
class="column-5">Remote reset</td></tr><tr
class="row-17 odd"><td
class="column-1">25</td><td
class="column-2">Logic Inputs</td><td
class="column-3">4+</td><td
class="column-4">Switch 4</td><td
class="column-5">Permissive Input</td></tr><tr
class="row-18 even"><td
class="column-1">26</td><td
class="column-2">Logic Inputs</td><td
class="column-3">C-</td><td
class="column-4">Signal ground</td><td
class="column-5"></td></tr><tr
class="row-19 odd"><td
class="column-1">27</td><td
class="column-2">Out 1</td><td
class="column-3">+</td><td
class="column-4">Output ch 1 (+)</td><td
class="column-5">Process control output</td></tr><tr
class="row-20 even"><td
class="column-1">28</td><td
class="column-2">Out 1</td><td
class="column-3">-</td><td
class="column-4">Output ch 1 (-)</td><td
class="column-5">Process control output</td></tr><tr
class="row-21 odd"><td
class="column-1">29</td><td
class="column-2">Out 2</td><td
class="column-3">+</td><td
class="column-4">Output ch 2 (+)</td><td
class="column-5">Advanced Option</td></tr><tr
class="row-22 even"><td
class="column-1">30</td><td
class="column-2">Out 2</td><td
class="column-3">-</td><td
class="column-4">Output ch 2 (-)</td><td
class="column-5">Advanced Option</td></tr><tr
class="row-23 odd"><td
class="column-1">31</td><td
class="column-2">RELAYS</td><td
class="column-3">RC</td><td
class="column-4">Relay Common</td><td
class="column-5"></td></tr><tr
class="row-24 even"><td
class="column-1">32</td><td
class="column-2">RELAYS</td><td
class="column-3">R1</td><td
class="column-4">Relay 1</td><td
class="column-5">Single Stage Control</td></tr><tr
class="row-25 odd"><td
class="column-1">33</td><td
class="column-2">RELAYS</td><td
class="column-3">R2</td><td
class="column-4">Relay 2</td><td
class="column-5">Dual Stage Control</td></tr><tr
class="row-26 even"><td
class="column-1">34</td><td
class="column-2">RELAYS</td><td
class="column-3">R3</td><td
class="column-4">Relay 3</td><td
class="column-5">Advanced Option</td></tr><tr
class="row-27 odd"><td
class="column-1">35</td><td
class="column-2">RELAYS</td><td
class="column-3">R4</td><td
class="column-4">Relay 4</td><td
class="column-5">Advanced Option</td></tr><tr
class="row-28 even"><td
class="column-1">E</td><td
class="column-2">AC MAINS</td><td
class="column-3">E</td><td
class="column-4">Mains ground</td><td
class="column-5">AC power in 95-135 V<br
/> or 190-260 V</td></tr><tr
class="row-29 odd"><td
class="column-1">N</td><td
class="column-2">AC MAINS</td><td
class="column-3">N</td><td
class="column-4">Mains neutral</td><td
class="column-5">AC power in 95-135 V<br
/> or 190-260 V</td></tr><tr
class="row-30 even"><td
class="column-1">A</td><td
class="column-2">AC MAINS</td><td
class="column-3">A</td><td
class="column-4">Mains active</td><td
class="column-5">AC power in 95-135 V<br
/> or 190-260 V</td></tr><tr
class="row-31 odd"><td
colspan="3" class="column-1 colspan-3">RS232 port</td><td
class="column-4">9-pin serial port</td><td
class="column-5"></td></tr></tbody></table><div
class="divider top"><a
href="#">Top</a></div><h2>515 BF04 Dimension Drawings</h2><div
class="one_third"></p><h3>Part Number</h3><p>515.XXXXXX-BF04</p><p>See product codes to select required features</p><p>Default application software:</p><p>515-BF04-000000</p><p></div><div
class="two_third last"></p><h3><img
class="alignnone size-full wp-image-581" title="515-dimensional-drawings" src="http://www.contrec.co.uk/wp-content/uploads/2011/04/515-dimensional-drawings.gif" alt="515 batch/flow computer dimensional drawings" width="624" height="349" /></h3><p></div><div
class="clearboth"></div><div
class="divider top"><a
href="#">Top</a></div><h2>515  Specifications</h2><div
class="one_half"></p><h3><p
class="fancy_header"><span>Operating Environment</span></p></h3><h5>Temperature</h5><p>-20 °C to +60 °C (conformal coating)<br
/> +5 °C to +40 °C (no coating)</p><h5>Humidity</h5><p>0 to 95% non condensing (conformal coating)<br
/> 5% to 85% non condensing (no coating)</p><h5>Power Supply</h5><p>95&#8230;135 V AC or 190&#8230;260 V AC or<br
/> 12&#8230;28 V DC</p><h5>Consumption</h5><p>6W (typical)</p><h5>Protection</h5><p>Sealed to IP65 (Nema 4X) when panel mounted</p><h5>Dimensions</h5><p>147 mm (5.8&#8243;) width<br
/> 74 mm (2.9&#8243;) height<br
/> 167 mm (6.6&#8243;) depth</p><h3><p
class="fancy_header"><span>Display</span></p></h3><h5>Type</h5><p>Backlit LCD with 7-digit numeric display and 11-character alphanumeric display</p><h5>Digits</h5><p>15.5 mm (0.6&#8243;) high</p><h5>Characters</h5><p>6 mm (0.24&#8243;) high</p><h5>LCD Backup</h5><p>Last data visible for 15 min after power down</p><h5>Update Rate</h5><p>0.3 second</p><h3><p
class="fancy_header"><span>Non-volatile Memory</span></p></h3><h5>Retention</h5><p>&gt; 30 years</p><h5>Data Stored</h5><p>Setup, Totals and Logs</p><h3><p
class="fancy_header"><span>Approvals</span></p></h3><h5>Interference</h5><p><strong>CE</strong> compliance</p><h5>Enclosure</h5><p><strong> </strong>ATEX, FM, CSA and SAA approved enclosures available for hazardous areas</p><h3><p
class="fancy_header"><span>Real Time Clock (Optional)</span></p></h3><h5>Battery Type</h5><p>3 volts Lithium button cell (CR2032)</p><h5>Battery Life</h5><p>5 years (typical)</p><h3><p
class="fancy_header"><span>Analog Input (General)</span></p></h3><h5>Overcurrent</h5><p><strong> </strong>100 mA absolute maximum rating</p><h5>Update Time</h5><p>&lt; 1.0 sec</p><h5>Configuration</h5><p><strong> </strong>4-20 mA, 0-5V and 1-5V input</p><h5>Non-linearity</h5><p><strong> </strong>Up to 20 correction points (flow inputs)</p><h3><p
class="fancy_header"><span>4-20 mA Input</span></p></h3><h5>Impedance</h5><p>100 ohms (to common signal ground)</p><h5>Accuracy</h5><p><strong> </strong>0.05% full scale (20 °C)</p><p>0.1% (full temperature range, typical)</p><p></div><div
class="one_half last"></p><h3><p
class="fancy_header"><span>0-5 or 1-5 Volts Input</span></p></h3><h5>Impedance</h5><p>10 Mohms (to common signal ground)</p><h5>Accuracy</h5><p>0.05% full scale (20 °C)</p><p>0.1% (full temperature range, typical)</p><h3><p
class="fancy_header"><span>Logic Inputs</span></p></h3><h5>Signal Type</h5><p><strong> </strong><strong> </strong>CMOS, TTL, open collector, reed switch</p><h5>Overvoltage</h5><p><strong> </strong>30V maximum</p><h3><p
class="fancy_header"><span>Relay Output</span></p></h3><h5>No. of Outputs</h5><p>2 relays plus 2 optional relays</p><h5>Voltage</h5><p>250 volts AC, 30 volts DC maximum (solid state relays use AC only)</p><h5>Current</h5><p>3 A maximum</p><h3><p
class="fancy_header"><span>Communication Ports</span></p></h3><h5>Ports</h5><p>RS-232 port<br
/> RS-485 port (optional)<br
/> Infra-red port</p><h5>Baud Rate</h5><p>2400 to 19200 baud</p><h5>Parity</h5><p>Odd, even or none</p><h5>Stop Bits</h5><p>1 or 2</p><h5>Protocols</h5><p>ASCII, Modbus RTU, Printer</p><h3><p
class="fancy_header"><span>Transducer Supply</span></p></h3><h5>Voltage</h5><p>8 to 24 volts DC, programmable</p><h5>Current</h5><p>70 mA @ 24 V, 120 mA @ 12 V maximum</p><h5>Protection</h5><p>Power limited output</p><h3><p
class="fancy_header"><span>Isolated Output</span></p></h3><h5>No. of Outputs</h5><p><strong> </strong>1 configurable output (plus 1 optional)</p><h5>Configuration</h5><p>Pulse/Digital or 4-20 mA output</p><h3><p
class="fancy_header"><span>Pulse/Digital Output</span></p></h3><h5>Signal Type</h5><p>Open collector</p><h5>Switching</h5><p><strong> </strong>200 mA, 30 volts DC maximum</p><h5>Saturation</h5><p>0.8 volts maximum</p><h5>Pulse Width</h5><p>Programmable: 10 , 20, 50, 100, 200 or 500ms</p><h3><p
class="fancy_header"><span>4-20mA Output (Optional)</span></p></h3><h5>Supply</h5><p>9 to 30 volts DC external</p><h5>Resolution</h5><p>0.05% full scale</p><h5>Accuracy</h5><p>0.05% full scale (20°C)<br
/> 0.1% (full temperature range, typical)</p><p><strong>Important:</strong> Specifications are subject to change without notice.</p><p></div><div
class="clearboth"></div><div
class="divider top"><a
href="#">Top</a></div><h2>Ordering Information</h2><h3>Product Codes</h3><table
id="wp-table-reloaded-id-42-no-1" class="wp-table-reloaded wp-table-reloaded-id-42"><thead><tr
class="row-1 odd"><th
class="column-1">Model</th><th
colspan="7" class="column-2 colspan-7">Supplementary Code</th><th
class="column-9">Description</th></tr></thead><tbody><tr
class="row-2 even"><td
class="column-1">515</td><td
class="column-2"></td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7">-</td><td
class="column-8">BF04</td><td
class="column-9"></td></tr><tr
class="row-3 odd"><td
class="column-1">Enclosure</td><td
class="column-2">1</td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Panel mount enclosure</td></tr><tr
class="row-4 even"><td
class="column-1">Enclosure</td><td
class="column-2">2</td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Field mount enclosure (not yet available)</td></tr><tr
class="row-5 odd"><td
class="column-1">Enclosure</td><td
class="column-2">3/5</td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Explosion proof Ex410 with metric glands (5 specifies heater version)</td></tr><tr
class="row-6 even"><td
class="column-1">Enclosure</td><td
class="column-2">4/6</td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Explosion proof Ex410 with NPT glands (6 specifies heater version)</td></tr><tr
class="row-7 odd"><td
colspan="2" class="column-1 colspan-2">Output Options</td><td
class="column-3">0</td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">4 logic inputs, 1 isolated output, 2 relays (only relay type 1 is available), RS232 (DB9) communication port</td></tr><tr
class="row-8 even"><td
colspan="2" class="column-1 colspan-2">Output Options</td><td
class="column-3">1</td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">4 logic inputs, 2 isolated outputs, 4 relays, real-time clock data logging, RS232 (DB9) and RS485 communication ports</td></tr><tr
class="row-9 odd"><td
colspan="2" class="column-1 colspan-2">Output Options</td><td
class="column-3">2/3</td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">4 logic inputs, 2 isolated outputs, 4 relays, real-time clock data logging, RS232 (DB9) and Ethernet/RF communication ports (not yet available)</td></tr><tr
class="row-10 even"><td
colspan="3" class="column-1 colspan-3">Relay Type</td><td
class="column-4">1</td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Electromechanical relays only</td></tr><tr
class="row-11 odd"><td
colspan="3" class="column-1 colspan-3">Relay Type</td><td
class="column-4">2</td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">2 electromechanical and 2 solid state relays</td></tr><tr
class="row-12 even"><td
colspan="3" class="column-1 colspan-3">Relay Type</td><td
class="column-4">3</td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Solid state relays only (not yet available)</td></tr><tr
class="row-13 odd"><td
class="column-1">Power Supply</td><td
class="column-2"></td><td
colspan="2" class="column-3 colspan-2"></td><td
class="column-5">E</td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">For 220/240 VAC</td></tr><tr
class="row-14 even"><td
class="column-1">Power Supply</td><td
class="column-2"></td><td
colspan="2" class="column-3 colspan-2"></td><td
class="column-5">A</td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">For 110/120 VAC</td></tr><tr
class="row-15 odd"><td
class="column-1">Power Supply</td><td
class="column-2"></td><td
colspan="2" class="column-3 colspan-2"></td><td
class="column-5">D</td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">For DC power only 12-28 VDC</td></tr><tr
class="row-16 even"><td
class="column-1">Display Panel Options</td><td
class="column-2"></td><td
class="column-3"></td><td
colspan="2" class="column-4 colspan-2"></td><td
class="column-6">F</td><td
class="column-7"></td><td
class="column-8"></td><td
class="column-9">Fully optioned (with backlight, LCD backup and Infra-Red comms port)</td></tr><tr
class="row-17 odd"><td
class="column-1">PCB Protection</td><td
class="column-2"></td><td
class="column-3"></td><td
class="column-4"></td><td
colspan="2" class="column-5 colspan-2"></td><td
class="column-7">C</td><td
class="column-8"></td><td
class="column-9">Conformal coating - required for maximum environmental operating range. Recommended to avoid damage from moisture and corrosion.</td></tr><tr
class="row-18 even"><td
class="column-1">PCB Protection</td><td
class="column-2"></td><td
class="column-3"></td><td
class="column-4"></td><td
colspan="2" class="column-5 colspan-2"></td><td
class="column-7">N</td><td
class="column-8"></td><td
class="column-9">None - suitable for IEC standard 654-1 Climatic Conditions up to Class B2 (Heated and/or cooled enclosed locations)</td></tr><tr
class="row-19 odd"><td
class="column-1">Application Pack Number</td><td
class="column-2"></td><td
class="column-3"></td><td
class="column-4"></td><td
class="column-5"></td><td
class="column-6"></td><td
class="column-7"></td><td
class="column-8">BF04</td><td
class="column-9">Defines the application software to be loaded into the instrument</td></tr></tbody></table><div
class="divider top"><a
href="#">Top</a></div><div
class="one_half"></p><h3>Main Menu Variables</h3><p><table
id="wp-table-reloaded-id-44-no-1" class="wp-table-reloaded wp-table-reloaded-id-44"><thead><tr
class="row-1 odd"><th
class="column-1">Main Menu Variables</th><th
class="column-2">Default Units</th><th
class="column-3">Preferred Units</th><th
class="column-4">Variable Type</th></tr></thead><tbody><tr
class="row-2 even"><td
class="column-1">Mass</td><td
class="column-2">kg</td><td
class="column-3"></td><td
class="column-4">Total</td></tr><tr
class="row-3 odd"><td
class="column-1">Mass Flowrate</td><td
class="column-2">kg/min</td><td
class="column-3"></td><td
class="column-4">Rate</td></tr><tr
class="row-4 even"><td
class="column-1">Control Output</td><td
class="column-2">%</td><td
class="column-3"></td><td
class="column-4">Rate</td></tr><tr
class="row-5 odd"><td
class="column-1">Flowrate Deviation</td><td
class="column-2">%</td><td
class="column-3"></td><td
class="column-4">Rate</td></tr></tbody></table></p><p>Please specify the preferred units of measurement.</p><p></div><div
class="one_half last"></p><p><div
id="attachment_446" class="wp-caption alignnone" style="width: 466px"><img
class="size-full wp-image-446 " title="500-batch-enclosure" src="http://www.contrec.co.uk/wp-content/uploads/2011/04/500-batch-enclosure.jpg" alt="500 Series in Ex410 Enclosure" width="456" height="441" /><p
class="wp-caption-text">500 Series in Ex410 Enclosure</p></div></p><p></div><div
class="clearboth"></div><div
class="divider top"><a
href="#">Top</a></div><p>&nbsp;</p><h2>Product Manual Download</h2><div
class="download_box"><a
title="Product Manual Download" href="http://www.contrec.co.uk/wp-content/uploads/2011/09/515-BF04-OM.pdf" target="_blank">Click here to download the 515 BF04 product manual</a></div> ]]></content:encoded> <wfw:commentRss>http://www.contrec.co.uk/515-bf04-2/feed/</wfw:commentRss> <slash:comments>0</slash:comments> </item> <item><title>202A Loop Powered Rate Totaliser</title><link>http://www.contrec.co.uk/212a/</link> <comments>http://www.contrec.co.uk/212a/#comments</comments> <pubDate>Sun, 20 Feb 2011 07:39:36 +0000</pubDate> <dc:creator>Nick</dc:creator> <category><![CDATA[200 Series]]></category> <category><![CDATA[202a]]></category> <category><![CDATA[7 digits]]></category> <category><![CDATA[cenelec standards]]></category> <category><![CDATA[conversion factors]]></category> <category><![CDATA[csa standards]]></category> <category><![CDATA[current loop]]></category> <category><![CDATA[cutoffs]]></category> <category><![CDATA[differential pressure]]></category> <category><![CDATA[fancy header]]></category> <category><![CDATA[flowmeter]]></category> <category><![CDATA[internal batteries]]></category> <category><![CDATA[ip67]]></category> <category><![CDATA[Loop Powered]]></category> <category><![CDATA[low flow]]></category> <category><![CDATA[memory stores]]></category> <category><![CDATA[mounting bracket]]></category> <category><![CDATA[non volatile memory]]></category> <category><![CDATA[pulse output]]></category> <category><![CDATA[Rate Totaliser]]></category> <category><![CDATA[solid state relay]]></category> <category><![CDATA[totaliser]]></category> <category><![CDATA[vortex flowmeters]]></category> <category><![CDATA[wall pipe]]></category><guid
isPermaLink="false">http://www.contrec.co.uk/?p=92</guid> <description><![CDATA[Overview 202A Specifications Ordering Information When specifying please indicate model(s) required using the following method. Product Manual Download]]></description> <content:encoded><![CDATA[<h2>Overview</h2><div
class="two_third"></p><p>The 202A Loop Powered Rate Totaliser is designed to operate with any flowmeter which produces a 4-20mA output, including differential pressure devices, magnetic or vortex flowmeters. The 202A is powered entirely from the 4-20mA current loop and has a maximum of 2.5 volts drop across the input.</p><p>The Rate Totaliser is fully programmable with linear or square law input relationships, programmable span, cutoffs and conversion factors. A non-volatile memory stores all set up parameters and totals without the need for internal batteries or external power.</p><p>High and low alarms are standard via optically isolated solid state relay outputs. Alternatively, the high alarm output can be programmed to provide a scaled pulse output proportional to the total.</p><h4>Watertight enclosure</h4><p>The 202A Rate Totaliser is housed in a rugged, yet attractive, IP67 (Nema 4X) polycarbonate enclosure which is completely watertight. A wall mounting bracket is supplied as standard, while a 2&#8243; pipe mounting bracket is available as an option. Alternatively, the Model 202A can be supplied as a panel mount instrument.</p><h4>Intrinsically safe</h4><p>The Model 202A is certified as intrinsically safe to European CENELEC standards, and CSA standards for both the USA and Canada.</p><p></div><div
class="one_third last"></p><h3>Features at a glance</h3><ul><li>Powered by 4-20mA loop</li><li>Displays Rate, Total and<br
/> Accumulated Total</li><li>Linear or square law inputs</li><li>High and low flow rate alarm</li><li>Pulse output</li><li>Watertight to IP67 (Nema 4X)</li><li>Wall, pipe and panel mounting</li><li>Intrinsically safe</li><li>Fully programmable</li><li>CE Compliant</li></ul><p></div><div
class="clearboth"></div><div
class="divider top"><a
href="#">Top</a></div><h2>202A Specifications</h2><div
class="one_third"></p><h3>General</h3><h3><p
class="fancy_header"><span>Display</span></p></h3><p>LCD which is continuously powered.</p><h3><p
class="fancy_header"><span>Resettable Total</span></p></h3><p>7 digits with 10mm (0.4&#8243;) high digits. Resettable from front panel.</p><h3><p
class="fancy_header"><span>Accumulated Total</span></p></h3><p>Displayed when the Accumulated Total button is pressed.</p><h3><p
class="fancy_header"><span>Rate</span></p></h3><p>4 digits with 8.5mm (0.33&#8243;) high digits.</p><h3><p
class="fancy_header"><span>Span</span></p></h3><p>The units of measure per timebase (eg. gallons/sec) is programmable up to 999,999.</p><h3><p
class="fancy_header"><span>Decimal Points</span></p></h3><p>Decimal point positions are fully programmable for both rate and total.</p><h3><p
class="fancy_header"><span>Timebase</span></p></h3><p>Span can be programmed in units per second, minute, hour or day.</p><h3><p
class="fancy_header"><span>Signal Type</span></p></h3><p>4-20mA.</p><p></div><div
class="one_third"></p><h3>Physical</h3><h3><p
class="fancy_header"><span>Temperature</span></p></h3><p>Operating temperature: -20°C to 60°C.</p><h3><p
class="fancy_header"><span>Dimensions</span></p></h3><p>98mm (3.9&#8243;) high x 152mm (6.0&#8243;) wide x 43mm (1.7&#8243;) deep (cable glands not included).</p><h3><p
class="fancy_header"><span>Protection</span></p></h3><p>Sealed to Nema 4X or IP67 standards.</p><h3><p
class="fancy_header"><span>Cable Entry</span></p></h3><p>By cable glands.</p><h3><p
class="fancy_header"><span>Wall Mounting</span></p></h3><p>Universal mounting bracket supplied as standard.</p><h3><p
class="fancy_header"><span>Pipe Mounting</span></p></h3><p>A galvanised metal bracket is available which enables the Model 202A to be attached to a 2&#8243; vertical or horizontal pipe.</p><h3><p
class="fancy_header"><span>Panel Mounting</span></p></h3><p>Supplied with mounting brackets. Terminals accessible from rear. (Note that the panel mount version is not watertight.)</p><p></div><div
class="one_third last"></p><h3>4-20mA Input</h3><h3><p
class="fancy_header"><span>Resolution &amp; Linearity</span></p></h3><p>0.05% of span.</p><h3><p
class="fancy_header"><span>Accuracy</span></p></h3><p>0.05% of span @ 25°C. 0.1% (typ) of span, full temperature range.</p><h3><p
class="fancy_header"><span>Update Time</span></p></h3><p>0.5 seconds.</p><h3><p
class="fancy_header"><span>Connection</span></p></h3><p>Two wire.</p><h3><p
class="fancy_header"><span>Voltage Drop</span></p></h3><p>2.5 volts maximum.</p><p></div><div
class="clearboth"></div><div
class="divider top"><a
href="#">Top</a></div><p><img
class="alignnone size-full wp-image-874" title="202-mounting" src="http://www.contrec.co.uk/wp-content/uploads/2011/04/202-mounting.jpg" alt="202 Rate Totaliser Mounting Options" width="945" height="477" /></p><div
class="divider top"><a
href="#">Top</a></div><div
class="one_third"></p><h3>Alarm/Pulse Outputs</h3><h3><p
class="fancy_header"><span>Type</span></p></h3><p>Two solid state relay outputs suitable<br
/> for driving DC solenoids or external<br
/> relays. The outputs provide high and<br
/> low flow alarms; or pulse output and low<br
/> flow alarm.</p><h3><p
class="fancy_header"><span>Switching Power</span></p></h3><p>200mA. 30VDC maximum.</p><h3><p
class="fancy_header"><span>Saturation Voltage</span></p></h3><p>0.8VDC typical across the output in the<br
/> &#8220;on&#8221; state.</p><h3><p
class="fancy_header"><span>Isolation</span></p></h3><p>Both outputs are separately optoisolated.</p><h3><p
class="fancy_header"><span>Pulse Duration</span></p></h3><h5>(for pulse output)</h5><p>a. 1ms if output frequency &gt; 50Hz,<br
/> b. 10ms if output frequency is 5&#8230;50Hz,<br
/> c. 100ms if output frequency is &lt; 5Hz</p><p></div><div
class="one_third"></p><h3>Intrinsically Safe Parameters</h3><h3><p
class="fancy_header"><span>CENELEC Approval</span></p></h3><p>Type Ex ia IIB T4</p><h3><p
class="fancy_header"><span>CSAUS/C Approval</span></p></h3><p>Type Class 1, Groups C &amp; D</p><h3><p
class="fancy_header"><span>4-20mmA Input</span></p></h3><p>Ui = 28V maximum<br
/> Ii = 93mA maximum<br
/> Pi = 653mW maximum</p><h3><p
class="fancy_header"><span>Relay/Pulse Outputs</span></p></h3><p>Ui = 28V<br
/> Ii = 93mA<br
/> Pi = 653mW maximum</p><p></div><div
class="one_third last"></p><h3>Terminal Description</h3><p><strong><table
id="wp-table-reloaded-id-1-no-1" class="wp-table-reloaded wp-table-reloaded-id-1"><thead><tr
class="row-1"><th
colspan="2" class="column-1 colspan-2">Common all models</th></tr></thead><tbody><tr
class="row-2"><td
class="column-1">Number</td><td
class="column-2"></td></tr><tr
class="row-3"><td
class="column-1">3</td><td
class="column-2">4-20mA (-) Input</td></tr><tr
class="row-4"><td
class="column-1">4</td><td
class="column-2">4-20mA (+) Input</td></tr><tr
class="row-5"><td
class="column-1">5</td><td
class="column-2">Low Alarm (-)</td></tr><tr
class="row-6"><td
class="column-1">6</td><td
class="column-2">Low Alarm (+)</td></tr><tr
class="row-7"><td
class="column-1">7</td><td
class="column-2">High Alarm (-) or Pulse (-)</td></tr><tr
class="row-8"><td
class="column-1">8</td><td
class="column-2">High Alarm (+) or Pulse (+)</td></tr></tbody></table> </strong></p><p></div><div
class="clearboth"></div><p><img
class="alignnone size-full wp-image-871" title="202-side" src="http://www.contrec.co.uk/wp-content/uploads/2011/04/202-side.jpg" alt="202 Loop Powered Rate Totaliser by Contrec" width="945" height="669" /></p><div
class="divider top"><a
href="#">Top</a></div><h2>Ordering Information</h2><p>When specifying please indicate model(s) required using the following method.</p><p><img
class="alignnone size-full wp-image-1792" title="202A ordering" src="http://www.contrec.co.uk/wp-content/uploads/2011/09/202Aordering.jpg" alt="202A ordering" width="910" height="220" /></p><div
class="divider top"><a
href="#">Top</a></div><h2>Product Manual Download</h2><div
class="download_box"><a
title="Product Manual Download" href="http://www.contrec.co.uk/wp-content/uploads/2011/09/202A_manual.pdf" target="_blank">Click here to download the 202A product manual</a></div> ]]></content:encoded> <wfw:commentRss>http://www.contrec.co.uk/212a/feed/</wfw:commentRss> <slash:comments>0</slash:comments> </item> </channel> </rss>