505 Series
The 505 BC01 application is a dual stage batch controller for reliable measurement


505 – BC01

Overview

The 505 BC01 application is a dual stage batch controller for reliable measurement of preset quantities using a volumetric frequency input. Used as a single or dual stage contoller it is suitable for fast batch applications.

It provides the operator with clear local readout and can be controlled via communications in more automated systems. There is quick access to commonly used preset values directly from the front panel if access has been authorized. Automatic overrun compensation caters for system delays such as valve closure for precise volumes.

The instrument is compatible with a wide range of flowmeter frequency outputs, including millivolt signals, reed switches, Namur proximity switches and pulse trains via its smart front-panel program selection.

Calculations

The total and flowrate are derived from accurately measured frequency and the number of received pulses.

volume = pulses / k-factor

volume flow = frequency / k-factor

Automatic overrun compensation calculates the new valve closure point to ensure correct delivery by averaging the overrun amount from the last three complete batches.

The overrun compensation value is valid for a new preset value provided the stored overrun is less than 20% of the new preset.

Features at a glance

  • Tailored for volumetric frequency flow input
  • Single or Dual stage control
  • Quick access to common batch quantities
  • No-flow, leakage and overflow error detection
  • Remote RUN/STOP/RESET
  • Allows for non-linear correction
  • Storage of 100 transactions with time and date stamp
  • Selection of second language and user tags
  • Selectable protocols on serial ports including Modbus RTU and Printer output
  • Backlit display with LCD backup

BC01-3 batch controller diagram

Displayed Information

The front panel display shows the current values of the input variables and the results of the calculations. A list of the variables for this application and their type (total or rate) is shown at the end of this document.

The instrument can be supplied with a real-time clock for storage of up to 100 transactions with time and date stamps.

Communications

There are three communication ports available as follows:

  • RS-232 port
  • RS-485 port
  • Infra-red port (optional)

The ports are available for remote data reading, printouts and for initial application loading of the instrument.

 

Retransmission & Control Outputs

The instrument can retransmit any main menu variable.

The digital outputs can retransmit totals as pulses or operate as logic levels for control or error outputs. If the instrument has the advanced option, it outputs rates as a 4-20 mA signal.

Relay Outputs

The relay outputs 1 and 2 are used to control the flow of product for each delivery. These contacts are normally open and can be used to drive external relays, valves, pump circuits etc.

Software Configuration

The instrument can be further tailored to suit specific application needs including units of measurement, custom tags, second language or access levels. A distributor can configure these requirements before delivery.

Instrument parameters including units of measurement can be programmed in the field, according to the user access levels assigned to parameters by the distributor.

All set-up parameters, totals and logged data are stored in non-volatile memory with at least 30 years retention.

500 series batch computer

Terminal Designations

Terminal LabelDesignationComment
1RS485+RS485(+)
2RS485-RS485(-)
3RS485GComms ground
4RS232TxRS232 data OutSame RS232 port as DB9 connector
5RS232RxRS232 data inSame RS232 port as DB9 connector
6RS232CCTS (Clear to send)Same RS232 port as DB9 connector
7lo+4-20 mA outputAdvanced option
8SG-Signal Ground 0 V
9Li+Logic inputRemote Run
10D OUT1+Open collector o/p 1Digital outputs
11D OUT2+Open collector o/p 2Digital outputs
12li+Signal inputRemote stop/reset
13SG-Signal Ground 0 V
14Fi+Frequency inputVolumetric flow
15V0+8-24 volts DC output70 mA power limited
16G-DC Ground
17Vi+DC power inputDC power in 12-28 V
18SHEShield terminal
19RELAYSR1Relay 1Single Stage
20RELAYSRCRelay Common
21RELAYSR2Relay 2Dual Stage
EAC MAINSEMains groundAC power in 95-135 V
or 190-260 V
NAC MAINSNMains neutralAC power in 95-135 V
or 190-260 V
AAC MAINSAMains activeAC power in 95-135 V
or 190-260 V
RS232 port9-pin serial port

505 BC01 Dimension Drawings

Part Number

505.XXXXXX-BC01

See product codes to select required features

Default application software:

505-BC01-000000

505 series flow computer dimensional drawings

505  Specifications

Operating Environment

Temperature

0 °C to +60 °C (conformal coating)
+5 °C to +40 °C (no coating)

Humidity

0 to 95% non condensing (conformal coating)
5% to 85% non condensing (no coating)

Power Supply

95…135 V AC or 190…260 V AC or 12…28 V DC

Consumption

6W (typical)

Protection

Sealed to IP65 (Nema 4X) when panel mounted

Dimensions

147 mm (5.8″) width
74 mm (2.9″) height
167 mm (6.6″) depth

Display

Type

LCD with 7-digit numeric display and 11-character alphanumeric display (backlit optional)

Digits

15.5 mm (0.6″) high

Characters

6 mm (0.24″) high

LCD Backup

Last data visible for 15 min after power down (optional)

Update Rate

0.3 second

Non-volatile Memory

Retention

> 30 years

Data Stored

Setup, Totals and Logs

Approvals

Interference

CE compliance

Enclosure

ATEX, FM, CSA and SAA approved enclosures available for hazardous areas

Real Time Clock (Optional)

Battery Type

3 volts Lithium button cell (CR2032)

Battery Life

5 years (typical)

Frequency Input (General)

Range

0 to 10 kHz

Over Voltage

30 V maximum

Update Time

0.3 sec

Cutoff Frequency

Programmable

Configuration

Pulse, coil or NPS input

Non-linearity

Up to 10 correction points

Pulse

Signal Type

CMOS, TTL, open collector, reed switch

Threshold

1.3 volts

Coil

Signal Type

Turbine and sine wave

Sensitivity

15 mV p-p minimum

NPS

Signal Type

NPS sensor to Namur standard

Remote Logic Inputs

Signal Type

Voltage free contact, open collector

Relay Output

No. of Outputs

2 relays

Voltage

250 volts AC, 30 volts DC maximum

Current

3 A maximum

Communication Ports

Ports

RS-232 port
RS-485 port
Infra-red port (optional)

Baud Rate

2400 to 19200 baud

Parity

Odd, even or none

Stop Bits

1 or 2

Data Bits

8

Protocols

Modbus RTU, Printer*

Transducer Supply

Voltage

8 to 24 volts DC, programmable

Current

70 mA @ 24 V, 120 mA @ 12 V maximum

Protection

Power limited output

Pulse/Digital Output

Signal Type

Open collector, non-isolated

Switching

200 mA, 30 volts DC maximum

Saturation

0.8 volts maximum

Pulse Width

Programmable: 10 , 20, 50, 100, 200 or 500ms

4-20mA Output (Optional)

Supply

24 volts DC internal, non-isolated

Resolution

0.05% full scale

Accuracy

0.05% full scale (20°C)
0.1% (full temperature range, typical)

Important: Specifications are subject to change without notice. Printer protocol is available only if RTC option is installed.

Ordering Information

Product Codes

ModelSupplementary CodeDescription
505-BC01
Enclosure1Panel mount enclosure
Enclosure2Field mount enclosure (not yet available)
Enclosure3/5Explosion proof Ex410 with metric glands (5 specifies heater version)
Enclosure4/6Explosion proof Ex410 with NPT glands (6 specifies heater version)
Output Options0Basic - RS232 and RS485 serial ports, 2 relays, 2 pulse outputs, rear key input
Output Options1Advanced - also includes 4-20mA o/p and Real-time clock for printer output and logging (100 logs)
Extra Options29 way DB connector for RS232 serial port
Power SupplyEFor 220/240 VAC
Power SupplyAFor 110/120 VAC
Power SupplyDFor DC power only 12-28 VDC
Display Panel OptionsSStandard (no backlight, LCD backup or Infra-Red comms port)
Display Panel OptionsFFully optioned (with backlight, LCD backup and Infra-Red comms port)
PCB ProtectionCConformal coating - required for maximum environmental operating range. Recommended to avoid damage from moisture and corrosion.
PCB ProtectionNNone - suitable for IEC standard 654-1 Climatic Conditions up to Class B2 (Heated and/or cooled enclosed locations)
Application Pack NumberBC01Defines the application software to be loaded into the instrument

Main Menu Variables

Main Menu VariablesDefault UnitsPreferred UnitsVariable Type
VolumeLTotal
Volume FlowrateL/minRate

500 Series in Ex410 Enclosure

500 Series in Ex410 Enclosure

Product Manual Download