Overview
The 1030 Access Terminals provide an operator keyboard and display together with Touch Key and Smart Card authorisation. The terminals are designed for mounting at remote locations, in both hazardous and safe areas.
The 1030s are ideal for use in petroleum terminals at the gatehouse, weigh stations or at the loading rack, and can communicate with a computer automation system via an isolated RS485 communications line.
The 1030A offers the advantages of a rugged explosionproof enclosure, large dot matrix display and alphanumeric keyboard.
The 1030W is suited for use in non- hazardous areas and provides room to mount modems and transmitters inside the enclosure.
Features at a glance
- Large display
- 8 line x 30 characters/line
- Alphanumeric keyboard
- Hazardous Area Approval
- Touch Key or Smart Card Reader
- Weatherproof
- Isolated RS485 port
- Output relays for opening gate
- Rugged housings
The 1030A/1030W is designed to control access to secured sites.
The 1030A/1030W is designed to control access to secured sites, loading and unloading terminals and other locations. Entry and exit can be controlled by Touch Key or Smart Card.
Touch Keys
Touch Key technology offers a rugged and secure method of identification for both drivers and vehicles.
The Touch Keys produce a coded number, similar to a magnetic card, that can be read by the Model 1030. Unlike magnetic cards, however, the Touch Key numbers will not be corrupted through heavy use. Each key has a unique identification number laser etched into a microchip that will transmit the number when the key is momentarily pressed against the reader.
Driver or vehicle authorisation can be granted via a database of valid key numbers stored internal to the 1030. Alternatively, the key number can be sent to the office automation computer for authorisation.
Touch Keys are available as a key ring tag in a number of colours or as a Smart Card, where the actual touch button is mounted on a plastic card or badge, of similar size to a magnetic card.
Standard Touch Keys do not have a battery and, therefore, have an unlimited life span. The keys receive a very small amount of power from the reader, which is mounted on the front panel. For hazardous areas, an intrinsically safe isolation barrier inside the unit limits the power to microwatts, and both the keys and the reader are internationally certified for use in hazardous areas.
Computer Mode
In the computer mode all operations are controlled by the automation computer including:
- Reading the Touch Key or Smart Card and sending the ID code back to the computer.
- Displaying messages from the computer system.
- Transmitting keyboard entries back to the computer system.
- Activating a relay when commanded by the computer.
The relay can be programmed to operate in either an acknowledge mode or pulse mode.
In the pulse mode, the relay will remain closed for a pre-programmed time between 0.1 to 999.9 seconds. In the acknowledge mode, the relay will de-activate on sensing an external switch input.
Alternatively, the computer can send a command to de-activate the relay.
The standard protocol used in the Model 1030 is SLIP, originally developed for the internet, because it provides a very reliable, secure and efficient method to transfer information. SLIP conforms to the International Standards Organisation OSI recommendations for multi-layered protocols.
Stand-Alone Mode
The digital valve control output enables the flow profile to be programmed to ramp up at the start of the load and to ramp down prior to the end of the load.
With our field proven fine-tuning algorithm, accurate control of flow rate is ensured for all major brands of digital control valves.
Five point linearity correction will ensure that flow signals from a wide range of flow meters will be measured with high accuracy.
Specifications
Physical – Model 1030A
Keypad Buttons
Switches:
Flameproof with heavy duty actuators.
11 alphanumeric and 7 function keys.
Materials:
Stainless Steel.
Enclosure
Dimensions:
302mm (w) x 288mm (h) x 326mm (d)
Material:
Powder coated aluminium
Sealing:
IP66 (Nema 4X) weatherproof, fully O-ring sealed
Mounting:
Four 8 x 1.5 mm metric or 5/16” UNF threaded holes top and bottom
Weight:
Single enclosure - 22.5 kg (approx)
Shipping weight – 23.0 kg (approx)
Cable Connection:
Five 25mm x 1.5mm metric threaded holes or 2 x 1¼”
and 1 x 1” NPT holes
Touch Key Reader
Material:
Stainless Steel & Delrin
Physical – Model 1030W
Keypad Buttons
Switches:
Double actuator switches behind a membrane overlay.
11 numeric and 7 function keys.
Enclosure
Dimensions:
270.5mm (w) x 270mm (h) x 268.5mm (d)
Material:
Powder coated mild steel
Sealing:
IP66 (Nema 4X) weatherproof, fully O-ring sealed
Mounting:
Two 14mm diameter metric holes on the bottom
Weight:
Single enclosure - 9.4 kg (approx)
Shipping weight – 14.0 kg (approx)
Cable Connection:
Removable gland plate can be drilled to suit
Operational – you are here Nick
Displays
Alphanumeric:
112 x 62 mm backlit dot matrix LCD.
Note: Contrast can be adjusted via keypad.
Power Requirements
110V ac +10% -15%, 50/60Hz.
220V ac +10% -15%, 50/60Hz.
Operating Temperature (Ambient)
-10 to 60°C (-40°C with optional heater)
Communications
Port 1:
RS232/RS422/RS485 or isolated RS485
Port 1:
RS232/RS422/RS485
Interference
CE Compliance
Permissive Outputs
2 x Electromechanical relay rated at 1A @ 240V ac or 24V dc
Approvals
Hazardous area approvals for the enclosure include:
- European Approval Cenelec EEx d IIB T6
- USA & Canadian CSAUS/C for Class 1, Groups C & D
Approvals for the Touch Keys, Reader and barrier include:
- European Approval Cenelec EEx d [ia] IIB T5
- USA & Canadian CSAUS/C for Class 1, Groups C & D
Important: Specifications are subject to change without notice.
Dimensional Drawing
Product Codes
| Model | Supplementary Code | Description | ||||
|---|---|---|---|---|---|---|
| 1030 | - GC - | Access Terminal and Touch Key/Card Reader | ||||
| Style | A | Explosionproof enclosure | ||||
| W | Weatherproof enclosure | |||||
| Application Pack | GC | |||||
| Authorisation | 2 | Touch Key | ||||
| 3 | Other | |||||
| Glands, Approvals and Heater Options for Enclosures | A | SAA approved with 5 x M25 | ||||
| C | CSAus/c 2 x 1.25” and 1 x 1” | |||||
| D | CSA as above with Heater | |||||
| M | Cenelec with 5 x M25 | |||||
| N | Cenelec as above with Heater | |||||
| L | No gland holes | |||||
| Power Supply | 1 | 110 VAC | ||||
| 2 | 220 VAC | |||||
| 3 | DC Volts |