Overview
The 1010A is a powerful and intelligent loading system designed to manage the loading of petroleums and chemicals onto road tankers, rail cars and barges.
The 1010A offers the advantages of a robust explosionproof enclosure, large dot matrix display and alphanumeric keyboard. The 1010A can handle simultaneous loading on up to 4 arms.
The large backlit dot matrix LCD will display up to four separate totals as well as showing preset values, flowrates, operator prompts, and other operational information.
The 1010A also features an integrated Touch Key reader and an isolated RS485 communications port which eliminates the problems of earth loops and reduces electrical noise.
Applications
The Model 1010A is available with a range of Applications Packs, consisting of application software and hardware designed to meet the specific requirements of:
- Standard petroleum loading
- Loading aircraft refuelling trucks
- Railcar loading
- Chemical loading
- Bitumen & asphalt loading
- Chinese & other language displays
In addition, Contrec has developed a number of special Application Packs to meet the needs of customers in different countries or where non- standard requirements exist.
Communication protocols include the Contrec SLIP protocol for reliable and secure transmission of data, as well as an industry standard protocol (TOPS) which enables the two arm version of the 1010A to directly replace other electronic presets.
Features at a glance
- Stand-alone or Integrated
- System operation
- 1-Arm to 4-Arm simultaneous loading
- CENELEC and USA/Canadian
- Hazardous Area approval
- PIN or optional Touch Key Authorisation
- Temperature Compensation to
- API Tables
- Stores last 200 Transaction Reports
- Isolated RS485 Port
- Second RS485/422/232 Port
- 5 Point K-Factor Linearity
- Correction for Flowmeters
- Fully Programmable with a sealable metrology switch
1010 A Load Computer – Standalone or Integrated System
The Model 1010A can operate in a stand-alone mode or integrate with a terminal automation system.
Standalone
In the Stand-Alone mode, the Model
1010A will provide complete control of the loading rack, including:
- Authorising drivers & vehicles
- Prompting the driver to enter arm number, compartment number and preset quantity
- Prompting and checking that the vehicle earth or overfill is connected
- Simultaneous loading of up to 4 arms
The Model 1010A will manage all loading operations for single or multi- compartment vehicles and produce a bill of lading for the entire vehicle.
The last 200 vehicle loads are always stored in memory, so that tickets can be re-printed or transactions downloaded to a computer system at a later date.
Integrated System
Because the system is capable of authorising vehicles and generating prompts without reference to the automation system, the communication workload on the office computer is substantially less than if these
functions were fully controlled by the automation system, as is the case with most other presets.
This means that the cost of developing software drivers and automation programs is greatly reduced.
The standard protocol used in the Model 1010A is SLIP, originally developed for the internet, because it provides a very reliable, secure and efficient method to transfer information to the office computer system. SLIP conforms to the International Standards Organisation OSI recommendations for multi-layered protocols.
Alternative Protocol
An alternative protocol to SLIP is an industry standard protocol, termed TOPS. The TOPS protocol is available for 2 arm versions of the 1010A and enables the system to directly replace other presets, in many applications.
With TOPS protocol much of the standalone functionality is lost as all messaging and control is passed across to the terminal automation computer system. Essentially, the 1010A
becomes a two channel batch controller when operated in this mode with the added capability of an operator display, keyboard and Touch Key reader – all controlled by the automation system.
Touch Key Technology
Touch Key technology offers a rugged and secure method of identification for both drivers and vehicles.
The Touch Keys produce a coded number, similar to a magnetic card, that can be read by the Model 1010A.
Unlike magnetic cards, however, the Touch Key numbers will not be corrupted through heavy use. Each key has a unique identification number
laser etched into a microchip that will transmit the number when the key is momentarily pressed against the reader.
Driver or vehicle authorisation can be granted by the Model 1010A via a database of valid key numbers stored internal to the system. Alternatively, the key number can be sent to the office automation computer for authorisation.

Touch Keys are available as a key ring tag in a number of colours or as a card, where the actual touch button is mounted on a plastic card or badge, of similar size to a magnetic card.
Standard Touch Keys do not have a battery and have an unlimited life span. The keys receive a very small amount of power from the reader, which is mounted on the front panel of the Model 1010A. An intrinsically safe isolation barrier inside the Model
1010A limits the power to microwatts, and both the keys and the reader are internationally certified for use in hazardous areas.
Functionality
The Model 1010A has all the flow measurement and control functions expected of a leading preset. These include:
- Precision flow measurement, including pulse verification to API and ISO standards.
- Temperature Measurement
- Volume Correction to API tables for most petroleum products and to US and metric standards.
- Digital Valve Control.
- Additive Control outputs
- Pump demand outputs with programmable delays.
- Permissive inputs for overfill, vehicle ground and emergency stop
- Pulse Outputs
- Other digital inputs/outputs specific to user requirements.
The digital control output enables the flow profile to be programmed to ramp up at the start of the load and to ramp down prior to the end of the load.
With our field proven fine-tuning algorithm, accurate control of flowrate is ensured for all major brands of digital control valves.
Modular Design
The modular design of the electronics simplifies servicing. Should a fault develop in the electronics, modules can be simply changed over in the field by technicians with minimal training.
The need for highly specialised personnel and/or costly maintenance contracts is eliminated providing terminals and depots with a level of self- sufficiency otherwise not available.
Approvals
The Model 1010A complies with international metrology approvals including:
- European approvals to the OIML R117 standards with certification through NMI and PTB
- US NIST approval
- Canadian approval
- South African SABS
- Australian NSC
Hazardous area approvals for the enclosure include:
- European Approval
- Cenelec EEx d IIB T6
- USA & Canadian
- CSAUS/C for Class 1, Goups C & D
Approvals for the Touch Keys, Reader and barrier include:
- European Approval
- Cenelec EEx d [ia] IIB T5
- USA & Canadian
- CSAUS/C for Class 1, Goups C & D
CE & EMC standards
- EN50081-1 & EN50081-2
- EN50082-1 & EN50082-2
1010 A Dimension Drawings

Programable Set-up Parameters
General
Driver Authorisation
Touch Key/PIN/None
Truck Authorisation
Touch Key/PIN/None
Password Protection
Multi-level password protection
Time and Date
Year/Month/Day/Hours/Minutes
Volume Decimals Display
0.1 or 1
Accumulated Totals
Gross/Net
Valve Control
No Flow Timeout
0 to 999s
Valve Type
Digital Set/Stop or On/Off
Slow Flow
xxx l/m or g/m
Deadband
30 to 500 l/m or g/m
Response Time Factor
0.2 to 1.0
Slow Start Time
0 to 99s
Prestop Quantity
0 to 999 litres or gals
Maximum Preset Quantity
up to 99999 litres or gals
Arm Input (for each arm)
Pulse Type (Flowmeter)
Single or Dual
Dual Pulse cut-off frequency
0 to 99Hz
K-factor – Linear
Single point 0.001 to 50000.0
Non-linear
5 points 0.001 to 50000.0
Temperature Compensation
None/Jet Fuel/Gasoline/Diesel/Crude Oil,
Calculations are exact to API Std. 2540
Fluid Temperature Range
-10 to 50°C
Flowrate at Full Flow
xxxx l/m or g/m
Additive Output Pulse Rate
per 0 to 9999 litres or gals
Overrun Correction Amount
xxx litres or gals
Accumulated Total
0 to 99999999
Communications
Communications Device
Computer or printer
Load Scheduling
Enable/Disable (Computer only)
Communication Mode
RS232/RS422/RS485
Baud Rate
300 to 28,800
Parity
Odd/Even
Stop Bits
1 or 2
Gantry Number or Unit Address
1 to 31
Additive Injector
Additive Injector Type
Piston or Contrec 1020 Intelligent Injector
Pulse Output
Open Collector or 110/240V ac
Additive Pulse
0.5 to 10s
Number of 1020 Injectors
Up to 4 injectors per arm
Other Options
Initial Message
System Available, Connect System, Connect Overfill
Deadman Timer
Enable/Disable
Illegal Access
Enable/Disable
Alarm on Fault
Enable/Disable
Ask Load Number
Enable/Disable
Ask Compartment Number
Enable/Disable
Ask Return Quantity
Enable/Disable
Ask Trip Number
Enable/Disable
Expansion Mode
Enable/Disable
Keyboard Timeout
20 to 999 Seconds
Overfill/Earth Reconnect
20 to 999 Seconds
1010 A Specifications
Note that some specifications may vary depending on the application. Refer to the Application Pack Briefs for more details.
Physical
Displays
Alphanumeric:
112 x 62 mm backlit dot matrix LCD.
Note: Contrast can be adjusted via keypad.
Batch Total:
6 digit (10mm high) backlit LCD with automatic ranging.
Keypad Buttons
Switches:
Flameproof with heavy duty actuators.
11 alphanumeric and 7 function keys.
Materials:
Stainless Steel.
Weights & Measures Seal:
A program access switch, located on the side of the enclosure, can be affixed with a lead seal to prevent tampering.
Enclosure
Dimensions:
302mm (w) x 288mm (h) x 326mm (d)
Material:
Powder coated aluminium
Sealing:
IP66 (Nema 4X) weatherproof, fully O-ring sealed
Mounting:
Four 8 x 1.5 mm metric or 5/16” UNF threaded holes top and bottom
Weight:
Single enclosure - 22.5 kg (approx)
Shipping weight – 23.0 kg (approx)
Cable Connection:
Five 25mm x 1.5mm metric threaded holes or 2 x 1¼”
and 1 x 1” NPT holes
Touch Key/Magnetic Card Reader
Material:
Stainless Steel & Delrin
Operational
Power Requirements
110V ac +10% -15%, 50/60Hz.
220V ac +10% -15%, 50/60Hz.
Operating Temperature (Ambient)
-10 to 60°C (-40°C with optional heater)
Communications
Computer/Printer:
RS232/RS422/RS485 or isolated RS485
Expansion Port:
RS232/RS422/RS485
Port configuration may depend on the Application Pack.
Interference
CE Compliance
Inputs and Outputs
Flow Inputs
Input Frequency:
0 to 2000Hz. Single or dual (quadrature) inputs on each channel
0 to 8000Hz optional (non OIML units only)
Note: Dual pulse is for pulse verification only
and does not detect reverse flow
Pulse Integrity: (Dual pulse only)
If a pulse failure is detected the system will alarm and stop flow on that channel
Note: This is in accord with API Standards Chapter 5,
Section 5, AS2702 and ISO6551
K-factor – Linear:
Single point 0.001 to 50000.0
Non-linear:
5 points 0.001 to 50000.0
Temperature Inputs
Input Signal:
4-20mA or 4 wire RTD
Range:
-10 to 50°C
Input Circuit:
12 Bit A/D converter
Correction:
To API Table 24B/54B for gasoline, diesel, Jet fuel and Table 24A/54A for crude oil.
Overfill and Ground Inputs
Switched input from floating contact
Note: Relays on the overfill and ground systems must be floating (ie. not connected to other circuits) and suitable for switching low voltage signals
Emergency Stop Inputs
Switched input from floating contact
Note: Switches or relays on this input must be floating (ie. not connected to other circuits) and suitable for switching low voltage signals
Valve Control Outputs
(2 stage on/off or digital control valves)
8 x Isolated Solid State Relays (SSRs) rated 1A @ 240V ac.
Min. contact voltage:
24V ac Max.
Contact voltage:
265V ac
Optical Isolation:
2500Vrms
Current range:
0.02 to 1A ac
Max. surge current:
20A ac
Max. off-state leakage current:
20mA ac
Note: SSR are not suitable for switching dc voltages
Additive Outputs
Conventional Piston Injector:
SSR rated 1A @ 240V ac
1020 Intelligent Additive Injector:
Open collector transistor. 100mA (max) and 28 Volt dc (max)
Pump Demand Outputs
Electromechanical relay rated at 1A @ 240V ac or 24V dc
Alarm Outputs
1 x Electromechanical relay rated at 1A @ 240V ac or 24V dc
Power Outputs
12V dc for flowmeters (150mA max)
24V dc for temp. sensors (100mA max)
Important: Specifications are subject to change without notice.

Ordering Information
Product Codes
| Model | Supplementary Code | Description | ||||||
|---|---|---|---|---|---|---|---|---|
| 1010 A | - | - | ||||||
| Number of Arms | 1 | Number of Loading Arms | ||||||
| Number of Arms | to | Number of Loading Arms | ||||||
| Number of Arms | 4 | Number of Loading Arms | ||||||
| Application Pack | B S | Application software & input/output card combination | ||||||
| Application Pack | B A | - refer Application Pack Brief for more details | ||||||
| Application Pack | etc | |||||||
| Authorisation | 0 | None or PIN | ||||||
| Authorisation | 2 | Touch Key | ||||||
| Glands, Approvals and Heater Option for the Enclosure | A | SAA Approved with 5 x M25 | ||||||
| Glands, Approvals and Heater Option for the Enclosure | C | CSA NRTL/C 2 x 1.¼“ NPT & 1 x 1” NPT | ||||||
| Glands, Approvals and Heater Option for the Enclosure | D | CSA as above but with heater | ||||||
| Glands, Approvals and Heater Option for the Enclosure | M | Cenelec Enclosure with 5 x M25 | ||||||
| Glands, Approvals and Heater Option for the Enclosure | N | Cenelec as above but with heater | ||||||
| Power Supply | 1 | 110 Vac | ||||||
| Power Supply | 2 | 220 Vac | ||||||
| Power Supply | 3 | dc Volts | ||||||
| Display Type and Units of Measurement | N | Dot Matrix Display - Programmable Units | ||||||
| Display Type and Units of Measurement | S | Special Type | ||||||
| Metrology Approval | 0 | None | ||||||
| Metrology Approval | 1 | Austrailian NSC | ||||||
| Metrology Approval | 2 | Canadian Weights and Measures | ||||||
| Metrology Approval | 3 | NMI OIML R117 | ||||||
| Metrology Approval | 4 | USA NIST | ||||||